Sensors; Automatic Load Sensing; Unbalanced Load Detection System; Voltcheck - Bosch WAT Series Instruction Manual And Installation Instructions

Table of Contents

Advertisement

H

Sensors

A utomatic load sensing
S e n s o r s
The automatic load sensing function
adapts the water consumption ideally to
each programme depending on the
type of fabric and the load.
Unbalanced load detection
system
The automatic unbalanced load
detection system detects imbalances
and ensures even distribution of the
laundry by repeatedly starting and
stopping drum spinning.
If the laundry is extremely unevenly
distributed, the speed is reduced or the
spin cycle is not performed for safety
reasons.
Place large and small items of
Note:
laundry evenly in the drum. ~ Page 43

VoltCheck

depending on the model
The automatic voltage control system
detects an unauthorised voltage under-
usage. The colon on the Ready in
display is flashing. ~ Page 25
Once the supply voltage is stable again,
the colon of the Ready in display lights
up (Normal mode).
The detected voltage under-usage is
indicated in the further program
sequence by all three points lighting up
in the display.
Voltage under-usages can for
Note:
example result in program extensions
and/or a non-satisfactory spin result.
M

Setting the signal

Y ou can change the following settings:
S e t t i n g t h e s i g n a l
The volume of the buttons and
information signals (e.g. at the end
of the program) and/or
The volume of the button signals.
You will need to activate the setting
mode in order to change these settings.
Activating the setting mode
Select the Cottons program to
1.
position 1. The washing machine is
switched on.
Press the A button and, at the
2.
same time, turn the program selector
clockwise to position 2.Release the
button.
The setting mode is activated and the
preset volume for the information
signals appears in the display panel
(e.g. at the end of the program).
Changing the volume
Use the Finished in-time + or - button
to change the following settings at the
corresponding program selector
positions:
2: The volume of the information
signals and/or
3: The volume of the button signals.
0 = off, 1 = quiet,
2 = medium, 3 = loud,
4 = very loud
Exiting setting mode
You can now end the process and set
the program selector to the Off position.
The settings are saved.