■ Cables
This cable is
provided only with
WV-X8570N.
A
RJ45 Network cable
Connect an Ethernet cable (category 5e or better, straight) to the RJ45 Network cable.
IMPORTANT:
⿟ Use all 4 pairs (8 pins) of the Ethernet cable.
⿟ The maximum cable length is 100 m {328 feet}.
⿟ Make sure that the PoE device in use is compliant with IEEE802.3af standard.
⿟ When the Ethernet cable is disconnected once, reconnect the cable after around 2 seconds.
When the cable is quickly reconnected, the power may not be supplied from the PoE device.
B
Alarm I/O cable / 4P alarm cable (accessory)
Connect the 4P alarm cable (accessory) to the alarm I/O cable, and connect the external device
cable to the 4P alarm cable.
Note:
⿟ Off, input, and output of the external I/O terminal 2 and 3 can be switched by configuring the
setting. Refer to the Operating Instructions on the Panasonic support web site for further infor-
mation about the external I/O terminal 2 and 3 (ALARM IN2, 3) settings ("Off", "Alarm input",
"Alarm output" or "AUX output").
<Ratings>
⿟ ALARM IN1 (Black & white input / Auto time adjustment input), ALARM IN2, ALARM IN3
Input specification : No-voltage make contact input (4 V - 5 V DC, internally pulled up)
OFF
ON
⿟ ALARM OUT, AUX OUT
Output specification : Open collector output (maximum applied voltage: 20 V DC)
ON
OFF
* This illustration represents WV-X8570N
A
RJ45 Network
cable
: Open or 4 V - 5 V DC
: Make contact with GND (required drive current: 1 mA or more)
: 4 V - 5 V DC by internal pull-up
: Output voltage 1 V DC or less (maximum drive current: 50 mA)
cable (category 5e
Ethernet
or better, straight)
B
Alarm I/O cable
B
4P alarm cable (accessory)
C
Audio input cable (white)
D
USB terminal
(for installation
constructor)
X 8570