Hyco Microboil Instruction Manual

Hyco Microboil Instruction Manual

Automatic boiling water unit. available in 3-25 litre models

Advertisement

Microboil
Automatic Boiling
Water Unit
Available in 3-25 Litre models
Instruction Manual
Version 3.2 Jan 2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Microboil and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hyco Microboil

  • Page 1 Microboil Automatic Boiling Water Unit Available in 3-25 Litre models Instruction Manual Version 3.2 Jan 2015...
  • Page 2: Important Safety Points

    Thank you for purchasing from our Microboil range of wall mounted automatic boiling water units. Available in sizes ranging from 3 to 25 Litres, the Hyco Microboil is a great way to provide the hot drinks that will keep a busy work team happy and productive.
  • Page 3: Installation

    THIS UNIT MUST BE INSTALLED BY A SUITABLY QUALIFIED PERSON IN ACCORDANCE WITH THE LATEST EDITION OF THE IEE WIRING REGULATIONS AND THE UK WATER FITTING REGULATIONS. THE SUPPLY CORD CANNOT BE REPLACED BY THE USER. IF THE CORD IS DAMAGED THE APPLIANCE SHOULD BE RETURNED TO THE MANUFACTURER OR AN AUTHORISED SERVICE AGENT FOR REPLACEMENT.
  • Page 4 Step 3: Wall Mounting (Fixing) Mark mounting hole positions on wall, drill and locate fixing screws but leave screws protruding by approximately 4mm. Mount unit onto screws via keyhole slots in back of case and tighten screws fully (see right). Cold Water In Vent Step 4: Plumbing Connections (Inlet)
  • Page 5: User Operation

    Step 5: Electrical Connection Electrical connection should be made via a 13A switched fuse spur in accordance with the latest edition of the IEE Wiring Regulations. • Ensure a water supply is present prior to turning on the electrics. • This appliance MUST BE EARTHED. •...
  • Page 6: Care And Maintainance

    5. CARE AND MAINTAINANCE • Clean with a damp cloth only - do not use abrasives. • The unit is fitted with a resettable thermal cut-out located on the element, a reset should only be attempted when the power is off and by a competent person.
  • Page 7: Troubleshooting

    7.TROUBLESHOOTING Symptom Possible Cause Solution This could be normal - it can Allow sufficient time - water should get Unit fills but take up to 15 minutes to boil progressively warmer. takes a long time from cold. to heat up from first installation, Thermal cut out tripped.
  • Page 8 This product is guaranteed against faulty materials and manufacture for a period of one year from the date of purchase. Hyco will in its sole discretion replace, repair or refund any faulty unit. Incorrect installation, frost damage, and the consequences of limescale deposits are excluded.