Figure 6 :: Usb Communications; Figure 7 :: Analog Interface, Analog Voltage Output; Figure 8 :: Digital Interface, Digital Alarm Output - Lightware SF02 Product Manual

Table of Contents

Advertisement

SF02
Laser rangefinder
! !
!
USB interface
The SF02 has a mini USB interface that can be used to communicate with LightWare Terminal software on a PC. This connection also
provides power to the unit thereby presenting a quick way to test and configure the SF02. The associated serial port transmits at
! !
115200 baud with 1 stop bit and no parity or handshaking. More details are discussed in the "Menu options" section below.
!
!
Analog voltage output
The analog voltage interface on screw terminal 7 produces a linear voltage of between 0.0 V and 3.3 V that is proportional to the
measured distance. The actual distances of the 0.0 V and 3.3 V end points can be adjusted through the menu system. The analog
voltage can be measured by the host controller using any available analog-to-digital-converter (ADC). The voltage is updated 12
! !
times per second and has 10 bit resolution.
! !
!
Alarm output
The alarm output on screw terminal 6 is a digital warning signal that becomes active when an object is closer than a preset distance.
The alarm distance can be set using the menu system. The alarm is active high with an output of 3.3 V. This alarm signal can be
! !
connected to an available digital port pin on the host controller and read as: low = safe and high = alarm.
! !
! !
! !
! !
! !
SF02 Laser Rangefinder - Product Manual - Revision 4
Product manual
!

Figure 6 :: USB communications

!

Figure 7 :: Analog interface, Analog voltage output

!

Figure 8 :: Digital interface, Digital alarm output

!
!
!
!
!
7
! of !
14
© LightWare Optoelectronics (Pty) Ltd, 2013