System components
2.5

Further options for waste heat use/peak load boiler

As an option, for waste heat use only of a CHP, further
Bosch industrial boilers can be used.
2.5.1

Waste heat boiler HRSB

As alternative to a 4-draught industrial steam boiler, a
pure waste heat boiler can be used. This variant should
be preferred in case of retrofitting (existing boiler
system). A bypass already exists in the waste heat boiler.
1
11
10
Fig. 7
Simplified function diagram Bosch waste heat boiler HRSB and CHP (simplified depiction)
[1]
Flue CHP module
[2]
Flue bypass
[3]
Chimney
[4]
Economiser
[5]
Peak load steam boiler
[6]
Make-up water
[7]
Water service module WSM-V
[8]
Manifold
[9]
Consumer
[10] CHP
[11] Waste heat boiler
14
2
3
4
Fig. 6
Bosch waste heat boiler HRSB
5
9
8
7
Water/condensate
Steam
Flue gas
Systemlösung – 6 720 885 509 (2018/03)
6 720 819 535-11.1T
3
4
6
6 720 819 535-12.1T