Operation Conditions Chp - Bosch CHP CE 240 NE Technical Manual

4-draught steam boiler and chp with mec system
Table of Contents

Advertisement

System components
Unit
GenSet
Gas category
Power consumption
kW
Electrical output
kW
Thermal output
kW
Electrical efficiency
%
Type
Engine manufacturer
Engine model
Dimensions
Length
mm
Width
mm
Height
mm
Weight (empty)
kg
Generation of electricity
Generator
manufacturer
Generator type
Voltage/Frequency
V/Hz
Speed
1/min
Efficiency
%
generator
Temperature levels
LT mixture circuit
°C
Heating water
°C
without flue gas heat
exchanger
Flue gas temperature
°C
without flue gas heat
exchanger
Maximum flue gas
°C
temperature
Flue gas tube
dimension (KAT)
Flue gas mass flow
kg/h
rate (wet)
Available flue gas
mbar
back pressure
Flue gas back
mbar
pressure boiler
Flue gas limit values
CO
mg/m
NOx
mg/m
NMHC
mg/m
Table 2 Specifications CHP CE 1287 NE ... CHP CE 2000 NE
2.2.3

Operation conditions CHP

The following operating conditions are required to
maintain the warranty:
• Ensure dust and halogen-free cooling and
combustion air
• Ensure that the exhaust air and exhaust gas lines are
correctly dimensioned, and run them separately
• Maximum setup height without a drop in
performance: depending on model used 100 ... 500
meters above zero
• Ratio of starting/operating hours: 1 start to 6
operating hours averaged over the year
8
CHP CE 1287 NE CHP CE 1560 NE
Natural gas
2974
1287
664
43.3
Design
external flue gas
external flue gas
heat utilisation
heat utilisation
MTU
12V4000 L33
TCG 2020 V16
4800
2000
2300
12000
Stamford
PE734F
MJB 500 LA4
400/50
1500
96.5
43/40
85/75
440
550
DN 350/PN 10
DN 400/PN 10
6700
25
15
3
300
i.N.
3
250
i.N.
3
150
i.N.
CHP CE 1718 NE
Natural gas
Natural gas
3629
3991
1560
1718
819
974
43
43
Design
Design
external flue gas
heat utilisation
MWM
MTU
16V4000 L33
6300
5500
1800
2000
2500
2300
13400
15000
Marelli
Leroy-Somer
LSA 51.2
VL95 C6S/4P
400/50
400/50
1500
1500
97.1
96.5
44/40
43/40
85/75
85/75
426
426
550
550
DN 400/PN 10
8665
8940
25
25
15
15
300
300
250
250
150
150
• Methane count: 80
• Natural gas Hi = 10 kWh/m
• Maximum exhaust gas counterpressure depending on
GenSet motor manufacturer 40 ... 60 mbar
• Module only suitable for setup within a building
• The condensate and flue gas line are pressurized and
must be appropriately designed, and the operating
pressure must be demonstrated in a pressure test.
CHP CE 1999 NE CHP CE 2000 NE
Natural gas
4666
1999
1076
42.8
Design
external flue gas
external flue gas
heat utilisation
heat utilisation
MTU
20V4000 L33
TCG 2020 V20
5900
2000
2400
19000
Stamford
LV804T
MJB 560 LB4
400/50
1500
96.3
43/40
85/75
449
550
DN 450/PN 10
DN 450/PN 10
10458
25
15
300
250
150
3
Systemlösung – 6 720 885 509 (2018/03)
Natural gas
4588
2000
1053
43.6
Design
MWM
7820
1800
2680
18100
Marelli
400/50
1500
97.4
45/38
85/75
410
550
10983
25
15
300
250
150

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents