Bosch Uni 3000 F Operating Instructions Manual

Bosch Uni 3000 F Operating Instructions Manual

Oil/gas boiler, output range 120 to 1850 kw

Advertisement

Quick Links

Oil/gas boiler
Uni 3000 F
Output range 120 to 1850 kW
Operating Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Uni 3000 F

  • Page 1 Oil/gas boiler Uni 3000 F Output range 120 to 1850 kW Operating Instructions...
  • Page 2: Table Of Contents

    10 General information ....... . . 10 6 720 814 353 (2014/12) Uni 3000 F...
  • Page 3: Safety Instructions

    ▶ It is not enough to switch off at the control unit. ▶ Secure the heating system against unintentional reconnection. ▶ Adhere to country-specific rules and regulations when making the electrical connection, commissioning, servicing and carrying out maintenance. Uni 3000 F 6 720 814 353 (2014/12)
  • Page 4: Product Information

    Natural Gas I2H Biogas quality in line (Kerosene) (G31) (G20) with DVGWG 262 Fig. 1 Uni 3000 F oil/gas floor-standing boiler up to 1200 kW 35-second oil Control unit (Gas Oil) Boiler jacket Base frame Comment: The boiler must only be operated with the specified fuels.
  • Page 5: Information On Installation And Operation

    ▶ If building work is taking place in the installation room and creating a 6 720 806 032-02.1ITL Fig. 2 Uni 3000 F oil/gas floor-standing boiler from 1400 kW - lot of dust, shut the boiler down. A burner contaminated during 1850 kW building work must be cleaned before commissioning.
  • Page 6: Commissioning

    Follow the control unit's operating instructions. 6 720 806 032-47.1ITL Fig. 3 Control unit, example CFB 930 control High limit safety cut-out Boiler temperature controller F1, F2 Fuse Burner emergency operation switch Appliance on/off switch 6 720 814 353 (2014/12) Uni 3000 F...
  • Page 7: Correcting Burner Faults

    We will therefore be using a sealed unvented heating system to demonstrate how you can check the water pressure. All settings will have already been made by the installation engineer when the system was first commissioned. Uni 3000 F 6 720 814 353 (2014/12)
  • Page 8: 7.2.1 Checking And Correcting The Water Pressure

    ▶ Check operating pressure. If the pressure in the system drops below the values in Table 3, water must be topped up. ▶ Top up with water. ▶ Vent the heating system. ▶ Check the operating pressure again. 6 720 814 353 (2014/12) Uni 3000 F...
  • Page 9: Environment / Disposal

    Environment / disposal | 9 Environment / disposal Tips on energy saving Environmental protection is a key commitment of the Bosch Group. Economy mode Quality of products, efficiency and environmental protection are equally The appliance has been designed, so that the oil/gas consumption and important objectives for us.
  • Page 10: General Information

    ▶ Only use the fuel intended for your heating system. disinfection of your hot water system. Now you know how to heat economically with the Bosch appliance. Contact your installer should you have further questions - alternatively, We recommend you seek the advice of your heating write to us.
  • Page 11 | 11 Notes Uni 3000 F 6 720 814 353 (2014/12)