PVI 36TL Installation and Operation Manual (Rev H)
AC output terminal block
Internal grounding bar
Internal grounding stud
External grounding point
Figure 2.29 - AC Output and Ground Cable Connections
Figure 2.30 - AC Output and Ground Cable Set Up
DOCR-070588-H
Table 2.7 - Required Tools
No.
Tools
1.
#3 Phillips screwdriver
2.
1/4" flat head bit
3.
1/8" flat head bit
4.
Torque driver
5.
Diagonal pliers
6.
Wire stripping pliers
7.
Crimping pliers
Table 2.8 - Torque Values
Core wire
30 in-lbs (3.5 N-m )
14 in-lbs (1.6 N-m )
14 in-lbs (1.6 N-m )
14 in-lbs (1.6 N-m )
Pre-insulated end ferrule
4pcs
Pre-insulated end ferrule
Page 38 of 120