WARNING
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green
ground connector in terminal box.
Do not use an extension cord.
Failure to do so can result in death,
fire, or electrical shock.
7G.
Route direct wire through
conduit and connect wires as follows:
• Form ground wire into a hook and
wrap clockwise around ground
screw under washer. Tighten ground
screw securely.
ground
wire
direct
green ground
wire
• Use twist-on connectors of proper
size to connect direct wire to
16-gauge wire dishwasher wiring.
Connect black wires together and
white wires together.
7H.
Reinstall terminal box.
IMPORTANT: The tabs must be under
the terminal box as shown.
terminal
box
tabs
6
8.
Apply Teflon
compound to 90° elbow fitting and
connect fitting to water inlet valve.
Use adjustable wrench and tighten
elbow until snug and facing the
direction needed for your water fill
line installation.
IMPORTANT: If you are installing the
Hot Water Accessory Tank, go back to
its Installation Instructions and
complete the installation at this time.
apply Teflon
or pipe joint
compound
do not apply Teflon
tape or pipe joint
compound
9.
Connect the dishwasher water
fill line.
• Slide nut onto copper tubing about
1 inch (2.54 cm).
• Slide ferrule onto the tubing. Do not
position ferrule on end of tubing.
• Put tubing into fill fitting as far as it
will go.
connector
• Slide nut and ferrule forward and
start nut onto elbow threads. Be
careful when handling and
positioning copper tubing. It bends
and kinks easily.
• With copper tubing pushed into
elbow as far as it will go, use a 5/8"
open-end wrench and tighten the
compression nut securely.
10.
Connect hot and cold water
lines to faucet.
11.
Connect the sink and
dishwasher drain plumbing.
12.
Turn water supply on to both
dishwasher and sink faucet. Check for
leaks.
®
tape or pipe joint
®
tape
water inlet
valve
water fill line
connection
®
POWER SUPPLY CORD METHOD:
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions
can result in death, fire, or
electrical shock.
DIRECT WIRE METHOD:
WARNING
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green
ground connector in terminal box.
Do not use an extension cord.
Failure to do so can result in death,
fire, or electrical shock.
13.
Plug in dishwasher or
reconnect power.
IMPORTANT: The following steps must
be done before using the dishwasher,
to test and activate the GFCI.
14.
Press the reset button on the
GFCI. The indicator should be visible.
test
reset
indicator
15.
Press the test button on the
GFCI. The indicator should disappear.