Installation Instructions Original Instructions Stratix 2000 Ethernet Unmanaged Switches Catalog Numbers 1783-US5T Series B, 1783-US4T1F Series B, 1783-US4T1H Series B, 1783-US8T Series B, 1783-US6T2F Series B, 1783-US6T2H Series B, 1783-US7T1F Series B, 1783-US7T1H Series B, 1783-US16T Series B, 1783-US5TG Series B, 1783-US16T2S Series B,...
Page 2
Stratix 2000 Ethernet Unmanaged Switches ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.
Page 3
Stratix 2000 Ethernet Unmanaged Switches Environment and Enclosure This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in EN/IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating.
Page 4
Stratix 2000 Ethernet Unmanaged Switches Electrical Safety Considerations ATTENTION: Power to this equipment must be supplied from a source compliant with the following: SELV source approved to EN/IEC60950-1, EN/IEC61010-2-201 or EN/IEC62368-1 (ES1) European Hazardous Location Approval The following applies to products marked II 3 G: •...
Stratix 2000 Ethernet Unmanaged Switches WARNING: If you connect or disconnect the communications cable with power applied to this module or any device on the network, an electric arc can occur. This could cause an explosion in hazardous location installations.
Stratix 2000 Ethernet Unmanaged Switches Enclosure Requirements WARNING: When used in a Class I, Division 2, hazardous location, this equipment must be mounted in a suitable enclosure with proper wiring method that complies with the governing electrical codes. Clearance to front and rear panels must meet these conditions: •...
Stratix 2000 Ethernet Unmanaged Switches Ground the Switch Follow these guidelines: • Grounding resistance must be less than 5 . • For proper grounding, use a suitable ring terminal for the chassis ground screw, and minimum 2.5 mm (14 AWG) wire.
Stratix 2000 Ethernet Unmanaged Switches Connect the Power Supply WARNING: When you connect or disconnect the removable terminal block (RTB) with field side power applied, an electric arc can occur. This could cause an explosion in hazardous location installations. There is a power terminal connector on the top of the device. You must connect the power wires to the power terminal connector to provide power for the device.
Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, Rockwell Automation, Rockwell Software , and Stratix are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400...