DESIGN & DIMENSIONS OF VT3130 / VT3131 / VT3132:
2
3
21
20
19
23
18
22
24
17
16
15
14
13
12
11
957083
1.
Air outlet
2.
Evaporator
3.
Compressor
4.
Air inlet
5.
Enamelled container
6.
Pocket for sensor - thermometer
7.
Anode
8.
Supplementary heating
9.
Pocket for sensor – working phial
10. Anode*
11. Adjustable feet
12. Cold water inlet
13. Safety condenser
14. Foam
CONTROL PANEL
29. Control button push/rotary
30. Control panel (display)
31. Operating-/alarm lamp heat pump
32. Operating-/alarm lamp supplementary heating

INTEGRATED HEAT-FXCHANGER (COIL):

The DHW HP con be equipped with 1 (e.g. model VT3131) or 2 integrated heat exchangers (coils). The single coil versing
has a heat-exchange surface of 1m
upper (17) coil. If you are using supplementary heating from 2 different energy sources, for example solar-thermic and oil /
gas/ solid fuel boiler, the solar installations must be connected to the lower coil. For the 2-coil version and 1 supplementary
energy source (e.g. solar-thermic) it is also possible to connect both coils in series.
NOTE: The temperature in the tank must not exceed 65°C. This must be ensured by a safety device controlled by the
maximum DHW temperature in the tank (1
might damage the heat pump's refrigerant circuit and is not covered by the product warranty.
5
6
8
9
7
10
957083
2
(20), whereas the double coil version has 1.5 m
st
priority) and a temperature limiter on the inflow side. Overheating the tank
Reprezentant unic in Romania - airguru.ro
19
20
23
18
24
17
16
12
ø707
957083
15. Heating coil (lower)*
16. Heating coil – inlet (lower)*
17. Heating coil – outlet (lower)*
18. Circulation connection
19. Hot water outlet
20. Defrost water outlet
21. Fan
22. Heating coil (upper)* *
23. Heating coil – outlet (upper)**
24. Heating coil – inlet (upper)**
*