Troubleshooting - Kenmore 625.34842 Owner's Manual

Demand special edition water softener
Table of Contents

Advertisement

SECTION 5
SERVICE TECH. INFORMATION
I
I
5A.
TROU B LES H OOTI N G
AUTOMATIC
ELECTRONIC
DIAGNOSTICS
The
face
plate
computer
has
a
self-diagnostic
function
for
the
electrical
system
(except
input
power
and water
meter).
The computer
monitors
the
electronic
components
and circuits
for correct
operation.
If a malfunc-
_.._
i"t__
tion occurs,
an error
code
appears
I_|
I
U_
in the face plate
display.
The chart
below
shows
the em)r
codes
that
couM
appear,
and the possible
ctefects
for each
code.
While
an error
code
appears
in the display,
all face
plate
buttons
are
inoperable
except
the
SELECT
button.
The SELECT button
remains
operational
so
the service
person
can
make
the Manual
Initiated
Electronic
Diagnostics
to further
isolate
the defect,
and check
the water
meter.
CODE
Err 01
Err 02
Err 03
Err 04
Err 05
POSSIBLE DEFECT
MOST LIKELY
-"
"--
LESS LIKELY
motor inoperative / wiring harness or connection to switch / position switch / face plate
face plate
motor inoperative / face plate
face plate / position switch
face plate
PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE: 1. Unplug transformer 2. Correct defect 3. Plug-in
transformer
4. Wait for 6 minutes. The error code will return if"the defect was not corrected.
MANUAL
INITIATED
ELECTRONIC
DIAG-
NOSTICS
1.
To enter
diagnostics,
press
and hold the SELECT
button
until 000
--
shows
in the ctisplay.
TURBINE
SWITCHES
nnn
___
I
uuu
_
p
-I--F ,
WATER
METER
(A)
SWITCH
(B)
The first 3 ctigits indicate water meter operation
as follows:
000 (stead39 =
Soft water not in use, and no
flow through
the meter.
i
OPEN A NEARBY
SOFT WATER FAUCET i
POSITION
SWITCH
_
MOTOR
VALVE
OUTLET
SENSOR
HOUSING
TURBINE
IRBINE
SUPPORT
AND
SHAFT
000 to 199 (continuaD
= Repeats display
for
each gallon of water passing through
the meter.
If you
don't
get a reading
in the
display,
with the
faucet
()pen,
pull the sensor
from
the valve
outlet
port.
Pass a small magnet
back
and forth
in front of
the sensor.
You should
get a reading
in the display.
If
you get a reading,
unhook
the in and out plumbing
and check
the turbine
for binding.
The letter (P) and clash (or dashes) indicate POSI-
TION switch operation.
If the letter appears,
the
switch is closed. If the clash shows, the switch is
()pen.
Use the ON/OFF-HOLD
(Recharge
Now) button
to manually
advance
the valve into each cycle
and check correct switch operation.
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

625.348420