Siemens SIMATIC IPC277E 19" INOX PRO Operating Instructions Manual
Siemens SIMATIC IPC277E 19" INOX PRO Operating Instructions Manual

Siemens SIMATIC IPC277E 19" INOX PRO Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC277E 19" INOX PRO:

Advertisement

Quick Links

SIMATIC
Industrial PC
IPC277E 19" INOX PRO
Compact Operating Instructions
05/2017
A5E37416443-AE
___________________
Preface
___________________
Product description
___________________
Safety instructions
___________________
Installing the device
___________________
Maintaining and repairing the
device
___________________
Specifications
___________________
Technical support
1
2
3
4
5
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC277E 19" INOX PRO

  • Page 1 ___________________ Preface ___________________ Product description ___________________ SIMATIC Safety instructions ___________________ Installing the device Industrial PC IPC277E 19" INOX PRO ___________________ Maintaining and repairing the device ___________________ Specifications Compact Operating Instructions ___________________ Technical support 05/2017 A5E37416443-AE...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    You can find the documentation of the basic device on the Internet at the following address: SIMATIC IPC277E documentation (https://support.industry.siemens.com/cs/ww/en/ps/21356/man) Conventions The term "device" is also used instead of the product designation in this document.
  • Page 4: Table Of Contents

    Table of contents Preface ............................3 Product description ........................5 Safety instructions ......................... 9 General safety instructions ....................9 Notes on use ........................10 Installing the device ........................11 Permitted mounting positions....................11 Mounting and connecting the device ...................11 Maintaining and repairing the device ..................... 17 Replacing the backup battery .....................17 Cleaning the device ......................20 4.2.1...
  • Page 5: Product Description

    Product description The following figures show the front and rear views of the IPC277E 19" INOX PRO. ① ④ Display with touch screen Connection compartment ② ⑤ Decorative foil Mechanical interface for fastening ③ ⑥ Position of nameplate and approvals Rear panel Features The housing of the IPC277E 19"...
  • Page 6 Product description Scope of delivery ● 1 x IPC277E 19" INOX PRO ● 1 x 2-pin connecting terminal for the 24 V DC power supply ● 1 x seal for mechanical interface Accessories Mounting kit for stand mounting A mounting kit is available for stand mounting of the device. Mounting kit contents: ●...
  • Page 7 Product description Service pack 2, only in combination with the service manual Service pack 2 contains: ● 1 spare seal for the rear panel of the device ● 4 spare screws for the rear panel of the device ● 1 spare seal for the mechanical interface of the device ●...
  • Page 8 The work described in the service manual may only be carried out by qualified specialist personnel who have been trained correspondingly by Siemens. The service manual is available online under "Product Support" next to this document in the same branch of the product tree.
  • Page 9: Safety Instructions

    Safety instructions General safety instructions WARNING Performing a function test when installing the device in machines or systems Following the results of a risk analysis, additional protection equipment on the machine or the system is necessary to avoid endangering persons. In particular, the programming, parameter assignment and wiring of the inserted I/O must be executed in accordance with the safety performance identified by the necessary risk analysis (SIL, PL or Cat.).
  • Page 10: Notes On Use

    Safety instructions 2.2 Notes on use Battery and rechargeable battery WARNING Risk of explosion and release of harmful substances Improper handling of lithium batteries can result in an explosion of the batteries. Explosion of the batteries and the released pollutants can cause severe physical injury. Worn batteries jeopardize the function of the device.
  • Page 11: Installing The Device

    Installing the device Permitted mounting positions The device may only be operated in landscape format with a maximum inclination of ±30° to the vertical. Permissible ambient temperature: 0 ... 45 °C Mounting and connecting the device This section describes how to mount and connect the device correctly, using stand mounting as an example.
  • Page 12 Note The device is fastened to a stand or a support arm via the mechanical interface with four screws. Siemens AG assumes no liability for the consequences of a faulty installation. WARNING The device must be mounted securely Inadequately dimensioned fastening material may cause the device to fall down. Serious bodily injury may result.
  • Page 13 Installing the device 3.2 Mounting and connecting the device Procedure 1. Open the connection compartment. To do so, remove the 6 screws on the device rear that are marked in the following figure and remove the connection compartment cover and associated seal. 2.
  • Page 14 Installing the device 3.2 Mounting and connecting the device 6. The following figure shows the position of the interfaces, the on/off switch and the battery box. ⑨ Switch off the device using the on/off switch ① ⑥ CFast slot Battery compartment ②...
  • Page 15 Installing the device 3.2 Mounting and connecting the device The protective conductor connection on the device must be connected to the protective conductor of the control cabinet or system in which the device is installed. WARNING Electric shock and fire hazard when protective conductor is not connected High voltage may be present in a defective device, which can cause fire or an electric shock if touched.
  • Page 16 Installing the device 3.2 Mounting and connecting the device Procedure ⑦ 1. Connect the protective conductor to the protective conductor connection accordance with the SIMATIC IPC277E operating instructions. The protective conductor connection is identified by the following symbol: The minimum cross-section of the protective conductor is 2.5 mm The protective conductor connection is needed to protect the device and helps ensure that interference signals generated by power lines, signal lines or lines to I/O devices are safely discharged to earth.
  • Page 17: Maintaining And Repairing The Device

    Maintaining and repairing the device Replacing the backup battery Prior to replacement WARNING Risk of explosion and release of harmful substances Improper handling of lithium batteries can result in an explosion of the batteries. Explosion of the batteries and the released pollutants can cause severe physical injury. Worn batteries jeopardize the function of the device.
  • Page 18 Maintaining and repairing the device 4.1 Replacing the backup battery Requirement ● The device is disconnected from the power supply. ● The connection compartment is open. Removing the battery NOTICE Time may be deleted The time will be deleted if it takes you longer than 30 seconds to replace the battery. The device is no longer synchronous.
  • Page 19 Maintaining and repairing the device 4.1 Replacing the backup battery Installing the battery To install the replacement battery, follow the steps for removing the battery in the reverse order. Velcro fasteners are provided with the replacement battery. 1. Connect the plug of the replacement battery with the device power supply cable.
  • Page 20: Cleaning The Device

    Maintaining and repairing the device 4.2 Cleaning the device Cleaning the device 4.2.1 Cleaning the Device Front The device is designed for low-maintenance operation. You should still clean the device front regularly, however. CAUTION Unwanted reactions when cleaning the device You risk unintentional actuation of operator controls if you clean the device while it is switched on.
  • Page 21: Clean Screen

    Maintaining and repairing the device 4.2 Cleaning the device Note Cleaning methods In addition to the specifications in this section, the following applies for cleaning the device: Permitted: Cleaning with strong jet water under increased pressure in accordance with DIN EN 60529:2014-09, specifications on "IP66". Not permitted: •...
  • Page 22: Chemical Resistance

    ● Diluted caustic solutions ● Ester ● Hydrocarbons ● Household cleaners You can find information of chemical resistance on the Internet (http://support.automation.siemens.com/WW/view/en/39718396). Seals The seals made of FPM (fluorinated rubber) are approved for food according to FDA regulations. 4.2.4 Working with stainless steel surfaces...
  • Page 23: Repair

    The device described in this document is covered by the conditions of repair and return of equipment, as follows: 1. You return the defective device to the returned goods center. The address is: Siemens AG Digital Factory Retouren-Center c/o Geis Service GmbH, Tor 1-4 Kraftwerkstraße 25a...
  • Page 24: Specifications

    DIN ISO 9001 certificate The quality assurance system for the entire product process (development, production, and marketing) at Siemens fulfills the requirements of ISO 9001. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 25 Specifications 5.1 Certificates and approvals cULus approval Underwriters Laboratories Inc., to ● UL 508 (Industrial Control Equipment) ● CSA C22.2 No. 142 (Process Control Equipment) or cULus approval, Hazardous Location cULus Listed INT. CONT. EQ. FOR HAZ. LOC. Underwriters Laboratories Inc., to ●...
  • Page 26 Specifications 5.1 Certificates and approvals ATEX/IECEx approval Special conditions of use The SIMATIC Industrial PC with article number 6AV7484-5AB..-0AA0 including the top side of the stand provides a degree of protection of at least IP66. The bottom side of the stand shall be connected to a certified enclosure, providing a degree of protection of at least IP54 according to IEC 60079-15 for gas and non-conductive dust and IP6X according to IEC 60079-31, for conductive dust, taking into account the environmental conditions under...
  • Page 27: Dimension Drawings

    Specifications 5.2 Dimension drawings Dimension drawings 5.2.1 IPC277E 19" INOX PRO IPC277E 19" INOX PRO Compact Operating Instructions, 05/2017, A5E37416443-AE...
  • Page 28: Mechanical Interface Of The Device

    Specifications 5.3 Technical specifications 5.2.2 Mechanical interface of the device Technical specifications 5.3.1 General technical specifications Weight Approx. 15 kg Power supply 24V DC (19.2 to 28.8 V) Short-term voltage interruption in Min. 20 ms (DC), max. 10 events per hour; min. 1 s accordance with Namur recovery time Rated power consumption (DC):...
  • Page 29 Specifications 5.3 Technical specifications Electromagnetic compatibility Emission standard EN 61000-6-4; CISPR 22:2010 Class A; FCC Class A Immunity with regard ± 2 kV in accordance with IEC 61000-4-4; burst to conducted ± 1 kV in accordance with IEC 61000-4-5; symmetrical surge interference on the ±...
  • Page 30: Environmental Conditions

    Specifications 5.3 Technical specifications Interfaces DisplayPort (DPP) Connection of display devices with DPP connection 4 USB ports, maximum 6 W USB load. 3 × USB 2.0, a maximum of 2 can be operated in high-current • mode at the same time 1 x USB 3.0, high current •...
  • Page 31: Power Supply

    Specifications 5.3 Technical specifications 5.3.3 Power supply 5.3.3.1 Power requirements of additional components Maximum permitted current consumption at the USB ports Auxiliary components Maximum permitted power consumption, Max. total power voltage +5 V USB device 3.0 High current 900 mA 6 W (for all USB devices) Low current...
  • Page 32: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (https://support.industry.siemens.com) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa-db/en/Pages/default.aspx) ●...

Table of Contents