Specifications
5.3 Technical specifications
5.2.2
Mechanical interface of the device
5.3
Technical specifications
5.3.1
General technical specifications
Weight
Power supply
Short-term voltage interruption in
accordance with Namur
Rated power consumption (DC):
Degree of protection
Quality assurance
The generation of the supply voltage with the line-side power supply must be realized as safety
1
extra-low voltage with safe electrical isolation, isolated as SELV according to
IEC/UL/EN/DIN-EN 60950-1 and LPS/NEC Class 2.
When all the covers are closed and all the connecting lines have been connected properly with the
2
device
28
1
Approx. 15 kg
24V DC (19.2 to 28.8 V)
Min. 20 ms (DC), max. 10 events per hour; min. 1 s
recovery time
Constant current, typical: 2 A
Continuous current, maximum: 4 A
IP66 all-round
according to DIN EN 60529:2014-09
2
In accordance with ISO 9001
Compact Operating Instructions, 05/2017, A5E37416443-AE
IPC277E 19" INOX PRO