Page 1
USER’S GUIDE AALUX2 SERIES ALUMINUM MINI ARCHITECTURAL BASEBOARD REPLACEMENT COMPONENT LIST INCLUDED AALUX2 MODELS This unit complies with the CSA and UL standards For further information or to consult this guide online, please visit our website at www.stelpro.com INSAALUX20918...
If needed, refer to a specialist (industrial and commercial buildings) who will be able to calculate these heat losses and optimize the required capacity or consult the “Online heating calculation” section of the Stelpro website (residential buildings).
Page 3
SPECIFICATIONS, TECHNICAL DRAWINGS & INSTALLATION SPECIFICATIONS COMERCIAL USE RESIDENTIAL USE DENSITY 150 W DENSITY 100 W VOLTAGE LENGHT WEIGHT PER LINEAR FOOT PER LINEAR FOOT CODE WATTS CODE WATTS VOLTS AALUX20603x – – 23 5/8 AALUX20904x AALUX20903x 35 7/16 AALUX21206x AALUX21204x 1200 47 1/4...
OPERATION, MAINTENANCE & TROUBLESHOOTING ELECTRICAL WIRING • This unit must be connected to an electrical power source according to the voltage of the unit chosen. • To ground the heater, you must connect the green wire coming from the circuit breaker panel to the green screw located inside the junction box of the heater. ELECTRICAL DIAGRAM Thermal Element...
Page 5
REPLACEMENT COMPONENT LIST REPLACEMENT COMPONENT LIST REF. # PART # DESCRIPTION REF. # PART # DESCRIPTION PROT-YYY LINEAR THERMAL PROTECTION M-ALUX20611A ALMOND GRILLE COVER (300 W) (AUTO.) M-ALUX20611W WHITE GRILLE COVER (300 W) EA0300-06-*** ELEMENT 300W (600 mm) M-ALUX20611CA ANODIZED GRILLE COVER (300 W) EA0450-09-*** ELEMENT 450W (900 mm) M-ALUX20911A...
. Stelpro reserves the right to examine or to ask one of its representatives to examine the product itself or any part of it before honoring the warranty. Stelpro reserves the right to replace the entire unit, refund its purchase price or repair a defective part.
Need help?
Do you have a question about the AALUX2 SERIES and is the answer not in the manual?
Questions and answers