Fluid Set Replacement - Graco HVLP EDGE II Operation - Repair - Parts

10 psi (0.07 mpa, 0.7 bar) maximum air working pressure / 50 psi (0.35 mpa, 3.5 bar) maximum fluid working pressure
Hide thumbs Also See for HVLP EDGE II:
Table of Contents

Advertisement

Setup

Fluid Set Replacement

Removal
1.
Perform Pressure Relief Procedure,
page 8.
2.
Remove retaining ring and air cap.
3.
Trigger the gun and remove fluid nozzle.
NOTICE
Trigger the gun whenever removing or
installing the fluid nozzle. This prevents the
fluid nozzle and needle seating surfaces
from being damaged.
NOTE: Edge II Plus guns contain air cap
guide and spring held in place by fluid nozzle.
Upon removal of fluid nozzle, set aside air cap
guide and spring.
10
4.
Move trigger slide from SPRAY position
(A) to NEEDLE REMOVAL position (B).
SPRAY
Position
A
5.
Remove needle from front of gun.
Do not use a pliers to remove needle.
Damage to the needle tip will cause leaking
at the fluid nozzle.
ti30850a
NEEDLE
REMOVAL
Position
B
NOTICE
3A4980B
ti30851a
ti30852a