Graco 960P Instruction Manual page 15

Turbine spray guns 50 psi (0.35 mpa, 3.5 bar) maximum inlet fluid pressure / 100 psi (0.7 mpa, 7 bar) maximum inlet air pressure
Table of Contents

Advertisement

Clean Spray Gun
1. Clean gun and cup by hand with compatible sol-
vent or place them in gun washer with trigger held
open; cycle washer as necessary to clean gun.
05293
Fig. 16
2. Remove air cap retaining ring (29), air cap (27),
spring and detent plate (25). See Fig. 17.
3. Trigger gun while removing fluid nozzle (19) with
nozzle wrench (P), provided. See Fig. 17.
4. Remove gun fitting (22) from back of gun. Remove
needle for cleaning.
CAUTION
Trigger the gun whenever you tighten or remove
the nozzle. This keeps the needle seat away from
the nozzle seating surface and prevents the seat
from being scratched.
19
P
25
27
29
Fig. 17
Maintenance
5. Soak air cap, detent plate and fluid nozzle in
solvent. At a minimum, clean air cap and fluid
nozzle daily. Use solvent and brush (R), provided.
See Fig. 18. Some applications require more
frequent cleaning. Keep all air cap holes clean.
Clean air cap horn holes with a non-metallic item to
avoid permanently damaging them.
Fig. 18
6. With gun pointed down, clean front of gun, using
brush and solvent.
7. Trigger gun while installing fluid nozzle (19) with
nozzle wrench (P). See Fig. 17.
8. Install spring (25) into front of gun.
9. Install detent plate (25) into gun housing with open
sockets (S) facing up; align detent plate tab (T)
with notch in gun housing. See Fig. 19.
10. Install air cap (27), aligning air cap balls (U) with
detent plate sockets (S). See Fig. 19. Secure air
cap with air cap retaining ring (29).
NOTE: If installed correctly, air cap will snap into four
definite positions, with no loose rotation.
S
T
25
Fig. 19
11. Lubricate gun after cleaning it as instructed on
page 16.
05291
CAUTION
R
27
U
S
308336
02856
02966
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

960960gf.75960 series960gf.5

Table of Contents