Table 14 - Geometry Acronyms - Siemens Sicore II Installation And Commissioning Manual

Table of Contents

Advertisement

Installation
In summary for installation and alignment the critical values required to be determined are:
·
Height (H) – Height of camera above road surface
·
Distance D (D) – Distance along the side of the road from the camera to the centre
of the capture zone
·
Skew (S) – Distance from the camera at the side of the road measured to the
centre of the capture zone
·
Parameter
Description
W
Width of the street or lane to be
captured (at road surface)
W1
Width of the street or lane to be
captured (at plate height)
H
Mounting height of Sicore above
road surface
D
Distance from Sicore to the
horizontal centre line within the
image area
V
Depth of View
V1
Distance to start of Field of View
from Camera
b
Camera Angle for horizontal
F
focal length
DCN
Distance Camera to Number plate
(calculated assuming a plate
50cm above the ground)
DCS
Distance Camera to Street
S
Horizontal Shift

Table 14 - Geometry Acronyms

Sicore II Installation and Commissioning Guide
667/HB/52600/000 Issue 2 Unrestricted
Default or result value
Result value: Width of capture zone
measured at the road surface.
Result value : Either two lane (7.8m) or
three lane (9.5m) note that these
values are at the licence plate height.
Default value
Result value : Take from table
Result value : Take from table
Result value : Take from table
Result value : Take from table
12.5, 16, 25 or 35mm for IR camera
Result value : Take from table (driven
by height and skew)
Result value : Take from table (driven
by height and skew)
Default Value : Driven by pole position
and skew to centre of capture zone
48