Calibration Procedure - Graco DataTrak kit Instructions And Parts

With pulse count and runaway protection
Hide thumbs Also See for DataTrak kit:
Table of Contents

Advertisement

Calibration Procedure

1. Press and hold
appears.
2. Press
once. Change flow rate units to
cycles/min.
3. Return to Run Screen. Press and hold
seconds to reset batch totalizer.
4. Dispense fluid from pump into a graduated con-
tainer.
5. Convert the actual volume dispensed to cubic centi-
meters (cc). See conversion chart.
Units Measured
Multiply by
Gallons (U.S.)
Gallons (Imp)
Liters
Quarts
Ounces (U.S.)
Ounces (Imp)
Cubic inches
Cubic feet
28,317
Pints
cc
6. Divide the actual volume dispensed (cc) by the
number of cycles indicated on the DataTrak batch
totalizer display.
7. Press
to enter the Setup screen. Enter the
number from Step 6 in field 2 of the Setup screen.
313840N
for 5 seconds until Setup menu
for three
To get
3785
cc
4546
cc
1000
cc
946
cc
29.57
cc
28.41
cc
16.39
cc
cc
473
cc
1
cc
DataTrak Operation