Graco DataTrak kit Instructions And Parts page 10

With pulse count and runaway protection
Hide thumbs Also See for DataTrak kit:
Table of Contents

Advertisement

DataTrak Operation
Symbol
10
Table 1: Diagnostic Codes
Code
Code Name
Runaway
Pump running faster than
set runaway limit.
E-3
Low Battery
Battery voltage too low to
stop runaway.
E--4
Service
Problem with stopping
Component 1
runaway.
E-4
Disconnected
Solenoid is disconnected. Solenoid unplugged.
Solenoid
E-6
Blown Fuse
Fuse is blown. Replace
fuse; see page 11.
Diagnosis
Increased air pressure.
Increased fluid output.
Exhausted fluid supply.
Low battery. Replace battery;
see page 11.
Damaged solenoid.
Damaged valve carriage.
Runaway protection may be
enabled with pump that is not
equipped with a runaway sole-
noid valve. Enter setup screen
and disable runaway protec-
tion.
Damaged solenoid wires.
Faulty solenoid or solenoid
wiring.
Extreme temperatures (above
140°F [60°C]).
Runaway protection may be
enabled with pump that is not
equipped with a runaway sole-
noid valve. Enter setup screen
and disable runaway protec-
tion.
Cause
313840N