Advertisement

Quick Links

Kit Instructions/Parts
DataTrak
For providing pump diagnostics and material usage information for diaphragm pumps.
Conversion Kits - DataTrak with Pulse Count and Runaway Protection
Endura-Flo
4D150 - 24Y304
Endura-Flo
4D350 - 24Y306
®
Husky
1050 - 24B777, 24B784, and 24B793
®
Husky
3300 - 24K861 and 24K862
Conversion Kits - DataTrak with Pulse Count
®
Husky
1050 and Husky
Replacement Parts Kits 24B771, 24B772, 24B796, 24B798, 24K863, and 24K864
See page 3 for model information, including agency approvals.
Important Safety Instructions
Read all warnings and instructions in
the Endura-Flo, Husky 1050 or Husky
3300 Air-Operated Diaphragm Pump
manual. Save all instructions.
®
Kits
®
3300 - 24B794 and 24B795
313840H
EN
Model 24B777 shown
ti14052a

Advertisement

Table of Contents
loading

Summary of Contents for Graco DataTrak 24B777

  • Page 1 Kit Instructions/Parts ® 313840H DataTrak Kits For providing pump diagnostics and material usage information for diaphragm pumps. Conversion Kits - DataTrak with Pulse Count and Runaway Protection Endura-Flo 4D150 - 24Y304 ™ Endura-Flo 4D350 - 24Y306 ™ ® Husky 1050 - 24B777, 24B784, and 24B793 ®...
  • Page 2: Table Of Contents

    Graco Standard Warranty ....20 DataTrak™ includes agency approvals listed Graco Information ......20 below.
  • Page 3: Datatrak Kits

    DataTrak Kits DataTrak Kits Conversion Kits Use to add data monitoring capabilities to an existing pump. Data Monitoring Pulse Count and Endura-Flo Endura-Flo Husky Husky Diaphragm Runaway Pulse 4D150 4D350 1050 3300 Pump Material Protection Count * 24Y304 34Y306 24B777 24K861 Aluminum ...
  • Page 4: Installation

    Installation Installation 4. Select the Diagnostic Codes card that matches the WARNING WARNING WARNING WARNING operator’s preferred language. Insert it in the inside of the DataTrak cover for quick reference. SPECIAL CONDITIONS FOR SAFE USE Equipment must comply with the following conditions to avoid a hazardous condition which can cause fire or explosion.
  • Page 5: Check Datatrak Operation

    Installation 6. Use the screw provided to attach the reed switch a. The DataTrak pump icon should move when the just behind the air inlet. Remove the muffler, if air motor changes direction. needed, for easier access. Rotate the air inlet fitting as needed so the wrench flat clears the reed switch.
  • Page 6: Datatrak Controls And Indicators

    DataTrak Controls and Indicators DataTrak Controls and Indicators AA Runaway Limit, in cycles per minute (user settable; PF Prime/Flush Key (Enables Prime/Flush mode. While in 00=OFF) Prime/Flush mode, runaway protection is disabled and AB Displacement (user settable) the batch totalizer [BT] will not count.) LED will flash while in Prime/Flush mode.
  • Page 7: Datatrak Operation

    DataTrak Operation DataTrak Operation Run Mode NOTE: The display (AE) will turn off after 1 minute to save battery life. Press any key to wake up the display. NOTE: For Husky pumps, DataTrak is factory set to 685 Runaway cc/cycle. This setting is accurate for pumping water at a medium speed on a Husky 1050 pump (approximately 1.
  • Page 8 DataTrak Operation NOTE: If the DataTrak does not reset, use a screwdriver Counter/Totalizer to push the solenoid release button on the side of the air To reset the totalizer, press any key to wake up the dis- valve. play, then press and hold for 3 seconds.
  • Page 9: Calibration Procedure

    DataTrak Operation Calibration Procedure 1. Press and hold for 5 seconds until Setup menu appears. 2. Press once. Change flow rate units to cycles/min. 3. Return to Run Screen. Press and hold for three seconds to reset batch totalizer. 4. Dispense fluid from pump into a graduated con- tainer.
  • Page 10 DataTrak Operation Table 1: Diagnostic Codes Symbol Code Code Name Diagnosis Cause Runaway Pump running faster than Increased air pressure. set runaway limit. Increased fluid output. Exhausted fluid supply. Low Battery Battery voltage too low to Low battery. Replace battery; stop runaway.
  • Page 11 Use only an approved replacement battery, shown in Energizer alkaline # 522 Table 2, and an approved fuse, shown in Table 3. Use of an unapproved battery or fuse will void Graco’s war- Varta alkaline # 4922 ranty and Intertek and Ex approvals.
  • Page 12 DataTrak Operation Replace Fuse Table 3. Approved Fuses DataTrak Part Fuse 1. Remove the screw, metal strap, and plastic holder. Number Series* Required 2. Pull the fuse away from the board. A or B 24C580 289822 C and later 24V216 3.
  • Page 13 DataTrak Operation 313840H...
  • Page 14: Parts

    Parts Parts Conversion Kits, Cycle Count and Runaway Protection Husky 1050 - 24B777 (Aluminum), 24B784 (Polypropylene), and 24B793 (Conductive Polypropylene) Husky 3300 - 24K861 (Aluminum) and 24K862 (Polypropylene) Aluminum ti14225a Plastic Plastic Aluminum ti14052a ti14226a 313840H...
  • Page 15 Parts Ref. Ref. No. Part No. Description No. Part No. Description AIR VALVE, kit ----- DATATRAK module (includes Parts 6a-6c) (see pages 11 and 12 for battery and fuse replacement information) 24B767 Husky 1050 Aluminum ----- CABLE 24B774 Husky 1050 Polypropylene ----- BRACKET, wall 24B776 Husky 1050 Conductive...
  • Page 16 Parts Conversion Kits, Cycle Count and Runaway Protection Endura-Flo 4D150 - Kit 24Y304 Endura-Flo 4D350 - Kit 24Y306 ti14225a 313840H...
  • Page 17 Parts Ref. Ref. No. Part No. Description No. Part No. Description AIR VALVE, kit ----- DATATRAK module (includes Parts 6a-6c) (see pages 11 and 12 for battery and fuse replacement information) 17H318 for 4D150 ----- BRACKET, wall 17H316 for 4D350 SOLENOID/REED SWITCH, kit ----- VALVE, air, smart...
  • Page 18 Parts Conversion Kits, Cycle Count Only Husky 1050 and Husky 3300 - 24B794 (Aluminum) and 24B795 (Polypropylene and Conductive Polypropylene) ti14224a Ref. Part No. Description ----- DATATRAK module (see pages 11 and 12 for battery and fuse replacement information) ----- CABLE, CAN ----- BRACKET, wall...
  • Page 19 Parts Replacement Kits Solenoid/Reed Switch Husky Husky 1050 3300 Air Valve Material Includes Plastic Reed switch and solenoid (4a), 24B771 24K863 bracket (4c), and fasteners (4b, 4d) Aluminum 24B772 24K864 Reed Switch Husky 1050 or Husky 3300 Air Valve Material Includes Plastic 24B796...
  • Page 20: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.

Table of Contents