Verification and Calibration for Option 020/022

This section includes verification and calibration procedures for the HP Dual Power Analyzer Options
020 or 022. Add these procedures to those described in Appendix B of the AC Source User's Guide.
The verification procedures do not check all the operating parameters, but verify that the ac source is
performing properly. Performance Tests, which check all the specifications of the ac source, are given in
the applicable ac source Service Manual.
Because the output of the ac source must be enabled during verification or calibration, proceed with
caution, since voltages and currents will be active at the output terminals.
Important
Perform the verification procedures before calibrating your ac source. If the ac source
passes the verification procedures, the unit is operating within its calibration limits and
does not need to be re-calibrated.
WARNING
LETHAL VOLTAGES. Ac sources can supply 424 V peak at their output. DEATH
on contact may result if the output terminals or circuits connected to the output are
touched when power is applied. These procedures must be performed by a qualified
electronics technician or engineer trained on this equipment.
Equipment Required
The equipment listed in the following table, or the equivalent to this equipment, is required for
verification and calibration.
Equipment
5-pin connector plug
Digital Voltmeter
1
Current Monitor
Load Resistor
Capacitor
(calibration only)
Function Generator
(calibration only)
HP-IB Controller
1
The 4- terminal current shunt is used to eliminate output current measurement error caused by voltage
drops in the load leads and connections. Connect the voltmeter directly to these current-monitoring
terminals.
22
Table B-1. Equipment Required
Characteristics
This connector is supplied with the ac source
when ordered with option 020 or 022.
Resolution: 10 nV @ 1 V
Readout: 8.5 digits
Accuracy: >20 ppm
0.01 Ω, ±200 ppm,
30 ohm, 100 Watts minimum
1.0 µF, 50 V
50 mV, 500 mV, 60 Hz sinewave capability
Full HP-IB capabilities
Recommended Model
HP p/n 0360-2681
HP 3458A
Guildline 7320/0.01
HP p/n 0160-3490
HP 33120A
HP Series 200/300 or equivalent