EMS EnviroStart Installation & Commissioning Manual

Single phase motor energy control

Advertisement

Quick Links

EnviroStart™
Single Phase
Motor Energy Control
Installation &
Commissioning Guide
Version 2.1 January 2009
4A through 25A
Single Phase Motor Energy Control - Page 1 of 20

Advertisement

Table of Contents
loading

Summary of Contents for EMS EnviroStart

  • Page 1 EnviroStart™ Single Phase Motor Energy Control Installation & Commissioning Guide Version 2.1 January 2009 4A through 25A Single Phase Motor Energy Control - Page 1 of 20...
  • Page 2 Single Phase EnviroStart™ Motor Energy Control IMPORTANT WARNING Failure to read and comply with this manual may result in damage to the EnviroStart Unit and driven equipment and may render the warranty invalid. 1. Only a competent electrician should carry out the electrical installation.
  • Page 3: Table Of Contents

    CONTENTS INTRODUCTION.......................4 FEATURES ......................4 CORRECT ENVIROSTART SELECTION ................5 CE DECLARATION OF CONFORMITY ..............6 GENERAL SPECIFICATION ....................7 GENERAL CONSIDERATIONS................7 GENERAL CONSIDERATIONS ................7 HARMONICS ......................8 HEAT LOSSES ...................... 8 CONTROL PANELS WITH MULTIPLE SYSTEMS ..........8 IMMUNITY FROM INTERFERENCE..............8 COIL SUPPRESSION ....................
  • Page 4: Introduction

    The EnviroStart is a high specification digital Soft-Start, Motor Energy Control available in models suitable for motors up to 15A. In addition to the provision of a soft-start, the EnviroStart MEC incorporates state of the art Motor Energy Control technology to substantially reduce the electricity consumption of synchronous electric induction motors whilst they are operating at less than their full load capacity.
  • Page 5: Correct Envirostart Selection

    EnviroStart is expected to operate outside the normal specifications and you are uncertain as to the selection of a unit please contact EMS (European) or your local Distributor, we will always be happy to assist to ensure your application is correctly supported.
  • Page 6: Ce Declaration Of Conformity

    CE DECLARATION OF CONFORMITY MANUFACTURERS DECLARATION OF CONFORMITY This declaration covers all EnviroStart SPMEC Control units. This product fulfils the following European Community Directives when applied as follows: Low Voltage Directive The above products fulfil the Low Voltage Directive 73/23/EEC, 89/336/EEC and 93/68/EEC amendment for industrial equipment;...
  • Page 7: General Specification

    2. The power should be disconnected before installation and only put back on once installation is complete. 3. The only motors for which the Single Phase EnviroStart is suitable are 110v AND 220V AC single-phase induction motors. (Also known as “Cage” or “Squirrel Cage” motors). EnviroStart cannot be used on DC motors, Switched Reluctance motors or any form of Three Phase motor.
  • Page 8: Harmonics

    4W/A at full conduction, 3.5 CONTROL PANELS/CABINETS WITH MULTIPLE UNITS If more than one EnviroStart is to be installed in a single enclosure the heat dissipation figures should be added together before selecting cooling system requirements. 3.6 IMMUNITY FROM INTERFERENCE EnviroStart generally has a high level of immunity to externally generated interference and as a zero volt switching control is a minimal contributor.
  • Page 9: Interface Connections

    14A/2.5mm/14AWG 14A/2.5mm/14AWG 110-SPMECG6-25A/60 220-SPMECG6-25A/60 The above detail refers to new installations, where the EnviroStart is fitted into an existing installation; cable should be rated according to the fuses already fitted. Single Phase Motor Energy Control - Page 9 of 20...
  • Page 10: General Installation Considerations

    4. INSTALLATION 4.1 GENERAL PROCEDURES The majority of 4A and 10A Single Phase EnviroStart units will be shipped pre-wired with five core cable suitable for the current rating of the unit. If this is the case then ignore the following section as it is not relevant to your installation. (Refer to the wiring diagram at the end of this Installation and Commissioning Guide for details of the cable connections).
  • Page 11: Pcb Connections

    Earth 4.2 SETTING UP All EnviroStart DIP Switches are polled continuously and it should be possible to make changes whilst the unit is running to change between operational modes. It is however good practice to make changes whilst the unit is switched off to ensure that the software is not “hung”...
  • Page 12: Commissioning

    If the fault light comes on for more than a short period, switch off the unit for five minutes to allow the EnviroStart to cool and then switch on again. If the fault lamp comes back on Single Phase Motor Energy Control - Page 12 of 20...
  • Page 13 (Please note there are no user serviceable parts within the EnviroStart). 4.3.3 ENERGY SAVING MODES 4.3.3.1 AUTOMATIC SAVING MODE The unit can be switched between DOL (Direct on Line) and Energy Saving mode by altering DIP Switch 1 as Table 1 below shows.
  • Page 14: Soft Start

    4.3.5 REFRIGERATION APPLICATION SETTING In all cases where EnviroStart is fitted to refrigeration compressors, a minimum period of two minutes should elapse between stopping and starting the compressor motor. This is to allow the system to shed its backpressure. In many systems such as those manufactured by...
  • Page 15: Led Indicators

    If you experience problems with the unit re-starting in such conditions then use the inbuilt timer feature of EnviroStart by switching DIP 6 into the “ON” position. This will cause the unit to always wait two minutes before a restart is allowed ensuring backstop pressures are equalized within the compressor circuit.
  • Page 16 Single Phase Motor Energy Control - Page 16 of 20...
  • Page 17 5.2 GENERALISED INSTALLATION DIAGRAM INSTALLATION AND COMMISSIONING GUIDE Single Phase Motor Energy Control - Page 17 of 20...
  • Page 18: Appendixes

    APPENDIX 1 CONNECTION AND WIRING DIAGRAM 4A AND 10A DIP Switch Setting MEC Mode and Saving Levels Cable Connection Main Supply with Auxiliary 240V Connection Indicators showing, Power On, Run and Fault Condition Twin 20mm Cable Glands Mounting Holes – 4 x 4mm Single Phase Motor Energy Control - Page 18 of 20...
  • Page 19: Connection And Switch Locations

    CONNECTION AND WIRING DIAGRAM 25A NO PICTURE IS AVAILABLE AT THIS TIME Single Phase Motor Energy Control - Page 19 of 20...
  • Page 20: Mechanical Drawing

    APPENDIX 2 Mechanical Drawings 4A and 10A Single Phase Motor Energy Control - Page 20 of 20...