CONNECTIONS

DMX512 control

A DMX512 data link is required in order to control the device via DMX. The device provides 3-pin XLR
connectors for DMX connection.
1
Connect the output of your DMX controller to the DMX input DMX IN of the device with a DMX cable.
2
Connect the DMX output DMX OUT of the device to the DMX input of the next unit in the chain. Always
connect one output to the input of the next unit until all units are connected.
3
At the last unit, the DMX cable has to be terminated. Plug the terminator with a 120 Ω resistor between
Signal (–) and Signal (+) in the DMX output of the last unit.
4
If the cable length exceeds 300 m or the number of DMX devices is greater than 32, it is recommended
to insert a DMX level amplifier to ensure proper data transmission.
XLR connection:

Connection to the mains

The device uses an auto-range power supply that accepts input voltages between 100 und 240 volts.
1
Connect the LED module via the enclosed signal cable with the control unit. The LED module is powered
by the control unit.
2
Connect the device via the mains cable to a grounded mains socket. Thus the unit is switched on.
3
To switch off the unit, disconnect the power plug.
4
Do not connect the unit to the mains voltage via a dimmer. For a more convenient operation, use a
mains outlet which is switchable.
The device is equipped with a lockable power input connector. Plug in the power cord and turn it to the right
until it locks. Plug the power cord into a grounded electrical outlet that matches the rated voltage of the
machine.
21/28