OPTIONS EDIT

The optional modes that can be configured using the options menu
are—TOS LS LOGIC (N.O./N.C.), BOS LS LOGIC (N.O./N.C.), FOOT
TRIP (OFF/ON), SC SOL ON (SLOW/FAST), SC LS (N.O./N.C.), HI
ON BOS (OFF/ON), AND VALVE LS (N.O./N.C.).

OPTIONS EDIT

Turn the main power disconnect switch off. Select the OFF position on
the PROG/RUN key selector switch. Push and hold the ENTER button
on the keypad and turn the main power disconnect switch ON. Hold
the ENTER button until the display switch reads back OPTIONS EDIT.
Release the ENTER button.
The display now reads: TOS LS N.O.
Press the ENTER key to toggle between N.O. and N.C.
t
s
Press the
and
buttons to scroll to the next option.
The display now reads: BOS LS N.O.
Press the ENTER key to toggle between N.O. and N.C.
Press the
t
and
s
buttons to scroll to the next option.
The display now reads: FOOT TRIP OFF
Press the ENTER key to toggle between OFF and ON.
t
s
Press the
and
buttons to scroll to the next option.
The display now reads: SC SOL ON=SLOW
Press the ENTER key to toggle between SLOW and FAST.
t
s
Press the
and
buttons to scroll to the next option.
The display now reads: SC LS N.O.
Press the ENTER key to toggle between N.O. and N.C.
t
s
Press the
and
buttons to scroll to the next option.
The display now reads: HI ON BOS=OFF
Press the ENTER key to toggle between OFF and ON.
Press the
t
and
s
buttons to scroll to the next option.
The display now reads: VALVE LS N.O.
Press the ENTER key to toggle between N.O. and N.C.
After the correct information has been entered, select the RUN position
on the PROG/RUN key selector switch.
Rockford Systems, LLC
Call: 1-800-922-7533
SECTION 4 — PROGRAMMING
SSC-500 Hydraulic Press Solid-State Control
Figure 4.16
OPTIONS EDIT Flowchart
(Continued on next page.)