Clear Batch; Clear Batch; Batch Preset; Batch Preset - Rockford Fosgate SSC-500 Installation Manual

Control systems on hydraulic presses
Table of Contents

Advertisement

CLEAR BATCH

Select the PROG position on the Program/Run selector switch.
t
s
Press the
and
buttons on the keypad to scroll through the pro-
gram options. Press ENTER when the LCD displays CLEAR BATCH.
The display now reads: UP ARROW CONFIRM
s
Press the
button on the keypad to clear the batch counter, or press
the ENTER button to abort the clear and return to the main menu level.
The LCD again displays CLEAR BATCH.
Function
The 7-digit batch counter is used to count strokes in the single or
automatic modes of operation only and can be displayed when the
Program/Run selector switch is in the RUN position.

BATCH PRESET

Select the PROG position on the Program/Run selector switch.
t
s
Press the
and
buttons on the keypad to scroll through the pro-
gram options. Press ENTER when the LCD displays BATCH PRESET.
The display now reads: XXXXXXX
Where XXXXXXX = a number between 0 and 9999999.
t
s
Press the
and
buttons on the keypad to increase or decrease
the batch preset. Pressing and holding the arrow keys will change the
numbers at a rapid rate. Press ENTER to program the batch preset
to the displayed number and return to the main menu level. The LCD
displays BATCH PRESET again.
Function
The machine will cycle until it reaches this batch preset count. When
the batch counter reaches this preset number, the machine top stops
and the message PRESET REACHED is displayed. Press ENTER to
clear both the message and the batch counter.
Entering 0 will disable the BATCH PRESET.
Rockford Systems, LLC
Call: 1-800-922-7533
SECTION 4 — PROGRAMMING
SSC-500 Hydraulic Press Solid-State Control
Figure 4.5
CLEAR BATCH Programming Flowchart

CLEAR BATCH

ENTER
UP ARROW CONFIRM
OR
ENTER
MAIN
MENU
Figure 4.6
BATCH PRESET Programming Flowchart

BATCH PRESET

Selects the Program Menu
ENTER
Item BATCH PRESET
XXXXXXX = Current Batch
XXXXXXX
Counter Preset
Press the DOWN and UP
arrows to decrease or
increase the current preset
(0 Will Disable the Preset)
Program the BATCH PRESET
ENTER
time and return to Main Menu
MAIN
MENU
Numeric
Setting Type:
Range:
0000000 - 9999999
0000000
Factory Setting:
Selects the Program Menu
Item CLEAR BATCH
Display now reads...
Press the UP arrow to
confirm the clear or enter
to abort
(Continued on next page.)
27

Advertisement

Table of Contents
loading

Table of Contents