SECTION 4 — PROGRAMMING
SSC-500 Hydraulic Press Solid-State Control
USER INPUTS (continued)

INPUT #1 (2, 3, 4)

Select the PROG position on the Program/Run selector switch.
t
s
Press the
and
buttons on the keypad to scroll through the
program options. Press ENTER when the LCD displays INPUT # 1.
Programming is the same for all four inputs.
The display now reads: X FLT
Where X FLT is a fault message from the list in Figure 4.8 on page 28.
t
s
Press the
and
buttons on the keypad to scroll through the list of
fault messages. Press ENTER to program the fault message displayed.
The display now reads one of the following:
OFF (Disabled)
N.O. (Normally Open)
N.C. (Normally Closed)
t
s
Press the
and
buttons on the keypad to change the logic
options. Press ENTER to program the input logic displayed.
Next, the LCD displays one of the following:
E-STOP (Emergency Stop)
T-STOP (Top Stop)
t
s
Press the
and
buttons on the keypad to change the stop type.
Press ENTER to program the input logic displayed and return to the
main menu level. The LCD displays INPUT #1.
Function
The user inputs can be programmed to monitor and diagnose common
problems with auxiliary equipment on the machine. Examples are main
clutch/brake air pressure, dual solenoid pressure switch, lube system
pressure or level switches, motor overloads, load monitors, stock
buckle, and end of stock sensors. Refer to the wiring diagram sheet 2
for information on wiring the inputs to the proper terminals.
*Note: If block valve monitoring is enabled, only three (3) user inputs
will be available.
32
Figure 4.15
INPUT #1, 2, 3, 4 Programming Flowchart*
INPUT #X
Selects the Program Menu Item
ENTER
INPUT #X (X = 1, 2, 3, or 4 )
LUBE FLT
HIGH LUBE FLT
LOW LUBE FLT
LOW LUBE LEVEL
MAIN MTR OL FLT
Press the DOWN and UP
arrows to scroll through the
LUBE MTR OL FLT
list of messages
AUX MTR OL FLT
GUARD OPEN FLT
REAR GUARD FLT
LEFT GUARD FLT
RIGHT GUARD FLT
FEEDER FLT
LOAD MONITOR FLT
SAFETY BLK FLT
DIE PROTECTION FLT
STOCK BUCKLE
END OF STOCK
EXTRN CNTRL FLT
Press ENTER to assign
ENTER
the fault message
OFF
N.O.
N.C.
Press the DOWN and UP
arrows to change the logic
Press ENTER to
ENTER
select the Logic
E-STOP
T-STOP
Press the DOWN and UP
arrows to change the stop type
Press ENTER to select the
Stop Type and return to the
ENTER
MAIN MENU
MAIN
MENU
Setting Type:
List Selection
NA
Range:
Factory Setting:
C/B Air Flt/Off/E-Stop
(Continued on next page.)