Dickson KT8P0 Getting Started

Remote sensing temperature recorder

Advertisement

Quick Links

DICKSON
DICK
DICK
DICK
SON
SON
SON
GETTING STARTED
GETTING STARTED
GETTING STARTED
GETTING STARTED
7-day chart rotation
o
0 to 100
F
QUICK START
QUICK START
QUICK START
QUICK START
1. 1. 1. 1. Remove the protective pen cap(s).
2. 2. 2. 2. Connect Probe(s):
a.
KT8P0/2/3: Make sure the KTC probe is connected firmly to the Replaceable
Sensor and that the Replaceable Sensor is plugged in firmly to the chart recorder.
b. KT856: Make sure both KTC probes are plugged in firmly to the chart recorder.
3. 3. 3. 3. Insert batteries and plug in AC adapter (See Figure 3). KT8P0:4 AA batteries required;
KT8P2/3 & KT856: 4 AA batteries backup power only (See page 5 for backup life). Unit
will power on.
4. 4. 4. 4. The instrument will move pen(s) to the appropriate readings.
5. 5. 5. 5. Install the chart that matches the Dip Switch settings (See p.4).
Press the PEN
PEN HOME
HOME key to move the pen(s) to the outside of the chart. The pen(s) is
PEN
PEN
HOME
HOME
automatically raised off the chart.
Remove the old chart, place the new chart on the Chart Hub being certain that the edge
of the chart slides under the Chart Guide Clips located at the outside of the chart.
6. 6. 6. 6. Set the appropriate time. There are two ways to adjust the chart and set the appropriate
time:
a.
Set the chart time manually by inserting a coin into the groove in the chart hub
and turning clockwise until the correct hour (and day if applicable) on the chart is
referenced to the timing arrow (just to the right of the pen tip on the dial). Press
Pen
Pen Home
Home to move the pen(s) back onto the chart.
Pen
Pen
Home
Home
The following feature should be used for fine adjustments only.
b. To adjust the chart time, press and hold Adjust
located on the back of the unit next to the dip switch (see Figure 3).
The green LED will blink rapidly for about five seconds, then the LED will remain
solid green. While in this state the Adjust
backward (counter clockwise) and the Adjust
forward (clockwise).
Rotate the chart until the correct hour (and day if applicable) on the chart is
referenced to the timing arrow. Once you have set your chart, press the Pen
Home button to exit Chart Adjust Mode. The unit will take one minute to exit the
Home
Home
Home
Chart Adjust Mode once Pen
pen(s) back onto the chart.
c.
Place the KT8 recorder on a flat vibration-free surface. Be sure it is in a vertical
position and level. For best performance and longevity, the location should be a
clean environment, free from dust and corrosive fumes. Do not exceed
temperature specifications. Wall Mount:
recorder for wall mounting.
Dickson KT8P Manual V6 52418
Remote Sensing
Remote Sensing
Remote Sensing
Remote Sensing Temperature
Adjust- - - - Up
Up and Adjust
Adjust
Adjust
Up
Up
Adjust
Adjust- - - - Up
Adjust
Up button will move the chart
Up
Up
Adjust
Adjust- - - - Down
Adjust
Down button will move the chart
Down
Down
Pen
Pen Home
Pen
Home
Home
Home is pressed. Press Pen
Wall Mount:
Wall Mount: Keyhole slots are provided on the KT8
Wall Mount:
1
KT8P0/2/3 & KT856
KT8P0/2/3 & KT856
KT8P0/2/3 & KT856
KT8P0/2/3 & KT856
Temperature Recorder
Temperature
Temperature
Recorder
Recorder
Recorder
Adjust- - - - Down
Down buttons
Adjust
Adjust
Down
Down
Pen
Pen
Pen
Pen
Pen Home
Pen
Home
Home
Home to move the

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KT8P0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dickson KT8P0

  • Page 1 KT856: Make sure both KTC probes are plugged in firmly to the chart recorder. 3. 3. 3. 3. Insert batteries and plug in AC adapter (See Figure 3). KT8P0:4 AA batteries required; KT8P2/3 & KT856: 4 AA batteries backup power only (See page 5 for backup life). Unit will power on.
  • Page 2 A A A A larm larm ( ( ( ( Optional Optional) ) ) ) larm larm Optional Optional Pen 1: = Red Pen Pen 2: = Blue Pen Dickson KT8P Manual V6 52418...
  • Page 3 4). The red pen has a shorter arm and records channel 1 temperature. The pens are offset to allow the red pen to glide under the blue pen. The blue pen indicates the correct time and the red pen precedes it by 3/16 of an inch. Dickson KT8P Manual V6 52418...
  • Page 4 #6 up #4 up #5 down 0 to +1000 F/C* #6 up #4 up #5 up 0 to +2000 F/C* #6 down * A203 High Temp Probe required - Range not available on Model KT800 Dickson KT8P Manual V6 52418...
  • Page 5 • AC Power with Low Battery or No Battery - Blinks Red • Battery Only - Blinks Green • Battery Only (Low Battery) - Solid Red Note: KT8P0 operates on battery only and will blink one time every minute to conserve battery life. PEN HOME ADJUST...
  • Page 6 Note: It is recommended that you use a controlled chamber when determining if Calibration is necessary. Adjusting the pen locations in an open room is not recommended as humidity can vary greatly within a very small area. Dickson KT8P Manual V6 52418...
  • Page 7 NEED TO KNOW NEED TO KNOW The pen movement for the KT8P0 is slower than on the AC powered models in order to conserve battery power. In 24-hour mode the pen(s) will move every 1 minute and 30 seconds. In 7-day mode the pen(s) will move every 8 minutes and 30 seconds.
  • Page 8 WARRANTY WARRANTY Dickson warrants that this line of instruments will be free from defects in material and workmanship under normal use and service for a period of twelve months after delivery. This warranty does not cover routine calibration and battery replacement.

This manual is also suitable for:

Kt8p2Kt8p3Kt856Tk856

Table of Contents