Chemical
Rinse water required
MCC-3
1. Close the Inlet Sea Cock Valve.
2. If installed, put the Multi Media Filter Valves in the "Multi Media Filter Bypass" position during cleaning. See
figure in the topic
Multi Media Filter Backwash and Rinse
positioning.
3. Replace the Pre-filtration Cartridge with a new Sea Recovery Corporation-supplied Pre-filtration Element.
4. Fill a 10-gallon (37.8 liters) container with clean, potable water.
5. Configure the System for a Once-Through Rinse, as described within the topic
page 51.
6. Start the System in MANUAL MODE.
Note: System operation will deplete the fresh water in the container. Before depleting the water entirely,
touch the STOP button.
7. Once again, fill the container with 10 gallons (37.8 liters) of clean, potable water.
8. Add 1.5 lbs. (0.68 kg) of Sea Recovery Membrane Cleaning Compound MCC 1, MCC 2 or MCC 3 to the water
container and thoroughly mix the solution until the cleaning compound has dissolved.
9. Configure the system for a Recirculating Closed Loop configuration.
10. Start the System in MANUAL MODE and operate it in the Recirculating Closed-Loop configuration for 60
minutes. After 60 minutes STOP the System.
11. Configure the system for a Once-Through Rinse.
12. Start the System in MANUAL MODE to discharge the cleaning chemical to waste.
Note: System operation will deplete the fresh water in the container. Before depleting the water entirely,
touch the STOP button.
13. For the last time, fill the container with 10 gallons (37.8 liters) of clean, potable water.
14. Configure the system for a Recirculating Closed-Loop configuration.
15. Start the System in MANUAL MODE and operate it in the Recirculating Closed-Loop configuration for 10
minutes. After 10 minutes STOP the System.
16. Configure the system for a Once-Through Rinse.
17. Start the System in MANUAL MODE to discharge the rinse water to waste.
Note: System operation will deplete the fresh water in the container. Before depleting the water entirely,
touch the STOP button.
The system is now ready for additional cleaning, use or storage. If further cleaning is necessary, repeat Steps
4 to 17 for each additional cleaning.
18. If the System will be expose to freezing temperatures, please review
on page 55.
Cleaning water required
Cleaning water required
10
10
on page 44 for Multi Media Filter Bypass Valve
Draining Component Water (for Winterizing)
General Operation
Total water required
20
Once-through Configuration
on
75