Sharp AH-AP18DR Service Manual page 3

Room air conditioners
Hide thumbs Also See for AH-AP18DR:
Table of Contents

Advertisement

ITEMS
Cooling capacity
Moisture removal
Electrical data
Phase
Rated frequency
Rated voltage
Rated current
Rated input
Rated factor
Compressor
Type
Model
Oil charge
Refrigerant system
Evaporator
Condenser
Control
Refrigerant volume (R-410A)
De-lce system
Noise level
High
(at cooling)
Med.
Low
Fan system
Drive
Air flow quantity
High
(at cooling)
Med.
Low
Fan
Connections
Refrigerant coupling
Refrigerant tube size Gas, Liquid
Drain piping mm
Others
Safety device
Air filters
Net dimensions
Width
(Cartont dimensions)
Height
Depth
Net weight (Gross weight)
Note: The condition of star (
INDOOR UNIT
AH-AP18DR
kW
5.2
Liters/h
1.6
Single
Hz
50
V
220 – 240
A
9.2 – 9.3
kW
1.99 – 2.15
%
98 – 96
Hermetically sealed rotary type
5KS225DAA
470cc [RB68A or Freol AlPha 68M]
Louver fin and Grooved tube type
Louver fin and Grooved tube typ
Capillary tube
910g
Micro computer controled reverse sysetm
dB(A)
41
dB(A)
36
dB(A)
34
Direct drive
m
3
/min.
15.7
m
3
/min.
13.9
m
3
/min.
11.7
Cross flow fan
Flare type
1/2", 1/4"
O.D ø 20
Compressor: Internal protector
Fan motors: Thermal protector(Internal)
Fuse, Micro computer control
Polypropylene net (Washable)
mm
1040 (1155)
mm
325 (300)
mm
220 (385)
kg
16 (21)
) marked item are 'ISO5151:1994(E), condition T1'.
OUTDOOR UNIT
INDOOR UNIT
AU-A18DR
AH-AP24DR
6.7
2.2
12.7 – 13.1
2.62 – 2.76
94 – 88
5JS315DAB
700cc [RB68A or Freol AlPha 68M]
1380g
52
45
39
37
48
18.3
14.7
13.5
Propeller fan
Cross flow fan
Compressor: Internal protector
890 (1020)
1040 (1155)
645 (735)
325 (300)
327 (398)
220 (385)
51 (55)
16 (21)
3
AH/AY-AP18DR
AH/AY-AP24DR
OUTDOOR UNIT
AU-A24DR
54
46
Propeller fan
890 (1020)
645 (735)
327 (398)
60 (64)

Advertisement

Table of Contents
loading

Table of Contents