INSTALLATION
3
Wiring
Wire the cable to the door controller as shown below.
Power supply cable
Communication cable
Slave module
LED
Slave module
module
NOTE
* When more then 1 master module is installed on the door leaf, make sure that only one power
supply cable is connected to the operator otherwise initialization can not be completed.
All other master units will automatically function as a slave unit.
NOTE
Maximum of three sensor modules can be connected to one master module.
1.White
To the power supply
2.Brown
connector of
3.Green
the master module
4.Yellow
5.Grey
6.Pink
7.Blue
8.Red
9.Black
10.Violet
NOTE
When a test input is not required, set the dipswitch A7 to OFF.
Before starting the procedure, make sure that the power is turned OFF.
WARNING
When passing the cable through the hole, do not tear the shield otherwise it may
Danger of electric shock
cause electric shock or breakdown of the sensor.
Inserting LED module
4
Connect the communication cable of the LED module to the master or slave module.
Attach the spacer on the endcap side. Insert the LED module to the profile as shown below.
The LED module can be inserted to both side of the profile.
To Master / Slave
module
5
Placing the front cover
After ADJUSTMENTS are completed, place the front cover and endcaps.
ADJUSTMENTS
1
Dipswitch settings
Each Master module is equipped with Dipswitch A and Dipswitch B and each Slave module is equipped with
only Dipswitch B. Only dipswitch A of the master module connected to the door controler is applicable and
will reflect the settings to all connected master and slave units automatically.
Dipswitch A
A1
Non detection zone (A)
A2
Frequency
A3
Immunity
ON
A4
Presence timer
A5
For future use
A6
A7
Test input
A8
Test input delay
1-1.Setting the non detection zone
The non detection zone is the height measured from the floor up to the position where the sensor starts to detect.
The zone can be set by a combination with Dipswitch A1 & B1.
[Non detection zone value] = [Dipswitch A1 value] + [Dipswitch B1 value]
Side view
Dipswitch A1
Dipswitch B1
OFF : "15cm"
OFF : "+0cm"
OFF : "15cm"
ON : "+10cm"
Non detection
zone
ON : "35cm"
OFF : "+0cm"
ON : "35cm"
ON : "+10cm"
1-2.Setting the frequency
When installing the sensors on a double swing door make sure that the frequency on
each sensor is set differently.
1-3.Setting the immunity
Set Dipswitch A3 to ON when the sensor operates by itself (ghosting).
When Dipswitch A3 is set to ON ,the actual detection area may
NOTE
become smaller than Immunity off.
1-4.Setting the presence timer
The presence timer can be set by Dipswitch A4.
If an object remains in the detection area longer than the setting, LED
NOTE
indicator may blink fast Red. In this case, it is not Sensor failure.
After an object is removed, LED indicator will show solid Green.
1-5.Setting the test input and test input delay time
Set dipswitches A7 & A8 according to the instructions from the door controller.
Test input and Safety / Test output timing chart
High
Test input
OFF
A7
(from door controller)
Low
A7
ON
open
N.O.
Safety / test output
close
(to door controller)
open
N.C.
close
* The test input delay time is the time period between the test input and Safety / Test output.
LED
Slave module
module
Door
Master module *
Each module has three communication connectors.
Use the most convenient connector for the
installation site.
(+)
Power supply
}
12 to 24VAC ±10% , 12 to 30VDC ±10%
(-)
COM.
Safety / Test output 2
}
N.C.
Form C relay
Reverse impulse (Closing side)
N.O.
COM.
Safety / Test output 1
}
N.C.
Form C relay
Stop impulse (Opening side)
N.O.
(+)
Test input
}
Opto coupler / Voltage: 10 to 30VDC
(-)
NOTE
For LED status see
SPECIFICATION
Dipswitch B
B1
Non detection zone (B)
B2
Area width
B3
Self monitoring
ON
B4
Mounting side (Output select)
Only correctly initialising the sensor ensures
NOTE
the correct functioning of the dipswitches
(see chapter 2. Function switch)
Non detection zone
15cm
(5 7/8")
25cm
(9 13/16")
NOTE
35cm
The value is a reference for
(13 3/4")
a mounting height of 1.8 to 2.5m
45cm
(17 11/16")
( 5' 11" to 8' 2" ).
Setting1
A2
OFF
Immunity off
A3
OFF
60sec.
A4
OFF
Detection
Test input
t1(>t2)
* Test input delay time (=t2)
10msec.
t2
t2
OFF
1-6.Setting the area width
Set dipswitch B2 to "2 spots" when a narrow
detection area is required.
4spots
B2
OFF
Door
controller
2
Function switch
Only the master module is equipped with a function switch. The function switch of the master module that is
connected to the door controller is only applicable to reflect settings to all sensor modules connected.
NOTE
Make sure to use the function switch when the door is in the fully closed position.
2-1.Initialization
After a dipswitch setting change or when the power is supplied for the first time, the LED blinks red & green.
Push the function switch for more than 2 sec. and then the LED indicator on the master unit will switch off.
The LED indicator will start to blink green to indicate the number of connected sensor modules.
The LED indicator will start to blink yellow and red and the initialization is completed. The LED is now indicating
that you have to proceed a learning cycle.
2-2.Learning
Push the function switch for less than 2 sec. and then the LED indicator will start to blink yellow. The sensor will
learn the non detection zone.
Do not enter the detection area when the sensor is performing a learning cycle.
NOTE
When the initialization and the learning cycle is completed, the sensor will be in stand-by mode and
the LED will show solid green.
3
Area depth angle adjustment
The angle of each sensor module must be adjusted so that the door stops
before it comes into contact with an obstacle. After area angle adjustments,
start the learning as described in chapter 2.Function switch.
EN16005
After the adjustment, check the detection area.
CHECKING
Check the operation according to the chart below.
The door movement might become unstable right after the learning. The movement becomes
NOTE
stabilized after several openings and closings.
Always walk-test the detection area to ensure the proper operation.
Entry
Status
LED indicator
Safety / Test output1
(Stop impulse)
Safety / Test output2
(Reverse impulse)
INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS
WARNING
1. Always keep the front cover clean. If dirty, wipe it with a damp cloth. (Do not use any cleaner / solvent.)
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.
4. When LED indicator blinks Fast Red without any object in the detection area, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the front cover.
1. After applying power, wait 10 seconds then walk test detection area to ensure proper operation.
NOTE
2. Do not place any objects that move or emit light in the detection area. (e.g. Plant, illumination, etc.)
TROUBLESHOOTING
Problem
The sensor has no function Wrong power supply voltage
Incomplete initialization
(Red & Green blinking)
Initialization is not finished
(Red & Green blinking
Setting2
continuous)
Incomplete learning
A2
(Yellow & Red blinking)
ON
Learning does not start
(Twice Orange blinking)
Immunity on
Sensor operates by itself.
(Ghosting) or
learning is not finished.
A3
(Yellow & Red blinking
ON
continuous)
Sensor operates by itself.
A4
(Ghosting)
ON
The sensor functions
without the front cover
but not with it.
Sensor operation is not
linked to door movement.
Door remains open
or closed without any
object in the detection
area.
20msec.
A8
A8
ON
Manufacturer
OPTEX CO.,LTD.
5-8-12 Ogoto Otsu 520-0101, Japan
TEL.: +81(0)77 579 8700 FAX.: +81(0)77 579 7030
WEBSITE: www.optex.co.jp
1-7.Setting the self monitoring
When the door remains open or closed, please refer to the
TROUBLESHOOTING section. If the door still remains open or
closed, set dipswitch B3 to "Disable"
2spots
B2
EN16005
ON
Set Dipswitch B3 to "Enable".
.
1-8.Setting the mounting side
(output select)
By selecting the sensor position the outputs & LED indicator will
function as shown below :
Dipswitch B4
OFF :"Opening side
(output 1)"
ON :"Closing side
(output 2)"
Power OFF
Outside of
detection area
-
Stand-by
None
Solid Green
COM.
COM.
N.O.
N.O.
N.C.
N.C.
Possible cause
Set to the stated voltage.
Wrong wiring or connection failure
Check the wiring and connectors.
Initialization has not been conducted.
Push the function switch for more than 2 sec. for
Dipswitch setting is changed.
initialization.
More than 2 master modules are connected
Connect the power supply cable to only one
with power supply wire.
master module.
Initialization has not been conducted.
Push the function switch for less than 2 sec. for
learning.
Communication error
Check the communication wires or change wires.
Objects that move or emit light in the
Remove the objects.
detection area. (Ex.Plant, illumination, etc.)
Same frequency setting on double swing
Set the different frequencies. (Dipswitch A2)
door application.
The modules are affecting each other.
Change the module positions or adjust angles
Signal saturation.
or adjust the area width (Dipswitch B2).
The floor pattern is not plain or ‚
Set the immunity (Dipswitch A3) to "ON".
the door movement is irregular.
Extend the non detection zone.
Waterdrops on the front cover
Install in a place keeping the waterdrops off.
The module angle is changed.
Check the module angles.
The front cover is dirty.
Wipe the front cover with a damp cloth.
(Do not use any cleaner or solvent.)
The front cover is scratched
Replace ‚the front cover.
Connection error or
Check the wiring or mounting side setting.
wrong mounting side setting.
(Dipswitch B4)
Presence timer set to infinity and sudden
Push the function switch for less than 2 sec. for
change in the detection area.
learning. Or change presence timer setting.
(Dipswitch A4)
Signal saturation. (Slow Red blinking)
Change the module positions or adjust angles
or adjust the area width (Dipswitch B2).
Push the function switch for less than 2 sec. for
The sensor is affected by the floor color.
learning. Or extend the non detection zone.
Communication error. (Twice Orange blinking)
Check the communication wires.
The front cover on inner or outer side is dirty. Wipe the front cover with a damp cloth.
(Do not use any cleaner or solvent.)
Sensor failure. (Fast Red blinking)
Contact your installer or service engineer.
European Subsidiary
OPTEX Technologies B.V.
Tiber 2, 2491 DH The Hague, The Netherlands
TEL.: +31(0)70 419 41 00
E-MAIL: info@optex.nl
Enable
Disable
B3
B3
OFF
ON
LED
Output
indicator
Safety / Test output1
Solid Red
(detection)
(stop impulse)
Safety / Test output2
Solid Orange
(reverse impulse)
(detection)
Adjustable angle : 0° to +25°
Angle adjustment screw
Entry into
Entry into
opening side
closing side
detection area
detection area
Detection active
Detection active
Solid Red
Solid Orange
COM.
COM.
N.O.
N.O.
N.C.
N.C.
COM.
COM.
N.O.
N.O.
N.C.
N.C.
Possible countermeasures
FAX.: +31(0)70 317 73 21
WEBSITE: www.optex.nl

Advertisement

loading