Installation - venting
Table II:
Effective duct length
0 - 20 m
20 - 30 m
30 - 43 m
43 - 60 m
Flexible ducting has been used for the
following example. See Table I for addi-
tional duct length factors for other
types of ducting.
Example:
Side connection, left. . . . . . . . . . 6.00 m
Length (L). . . . . . . . . . . . . . . . . . 1.20 m
Lower radius (R) . . . . . . . . . . . . 0.50 m
Height (H). . . . . . . . . . . . . . . . . . 1.00 m
Upper radius (R) . . . . . . . . . . . . 0.50 m
Wall pipe with louvred vent . . . . 3.80 m
Effective duct length . . . . . . . . 13.00 m
26
All manuals and user guides at all-guides.com
Internal diameter
100 mm
110 mm
120 mm
130 mm
Result:
A duct diameter of 100 mm is adequ-
ate since the effective length is less
than 20 m as specified in Table II.