Dimm - HP PROLIANT ML350 G6 Maintenance And Service Manual

Hide thumbs Also See for PROLIANT ML350 G6:
Table of Contents

Advertisement

Full-height
o
To replace the component, reverse the removal procedure.
IMPORTANT:
Connecting it to the SATA drive may interfere with other installed media bay devices.
IMPORTANT:
boot at a time. Boot priority will go to SATA if media is inserted into the SATA optical drive. Boot
priority for PATA is not configurable. To boot PATA, remove the media from the SATA optical
device, or remove the SATA optical device.

DIMM

IMPORTANT:
these two types causes the server to halt during BIOS initialization.
To identify the DIMMs installed in the server, see "DIMM identification (on page 86)."
Power down the server (on page 27).
1.
Do one of the following:
2.
Unlock and remove the bezel
o
Extend the server from the rack.
o
Remove the access panel
3.
Remove the large redundant fan air baffle, if installed
4.
Remove the DIMM baffles
5.
Remove a fan, if necessary ("Fan" on page 34).
6.
Open the DIMM slot latches.
7.
All manuals and user guides at all-guides.com
Be sure to connect the right-angle end of the SATA data cable to the system board.
If both SATA and PATA optical devices are installed simultaneously, only one can
This server does not support mixing RDIMMs and UDIMMs. Attempting to mix
("Front
bezel" on page 29).
("Access
panel" on page 30).
("DIMM
baffle" on page 33).
("Large redundant fan air
Removal and replacement procedures 55
baffle" on page 32).