The human activity sensor will also scan for area of heat source and movement in a room.
Detection area
120º
7m
• The human activity sensor may:
- mistakenly detect an object with heat source & movement similar to human, such as pets, etc.
- mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
• Do not place large objects near the sensor and keep away heating units or humidifi er from the sensor's detection
area. They may cause sensor malfunction.
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Temperature
°C (°F)
COOL
HEAT
• Based on area activeness horizontal airfl ow direction will adjust either fi x
at predetermined position or swing left/right periodically.
• The human activity sensor performance is infl uenced by indoor unit
location, movement speed, temperature range, etc.
Indoor
DBT
Max.
32 (89.6)
23 (73.4)
Min.
16 (60.8)
11 (51.8)
Max.
30 (86.0)
Min.
16 (60.8)
Outdoor
WBT
DBT
43 (109.4)
26 (78.8)
16 (60.8)
11 (51.8)
-
24 (75.2)
18 (64.4)
-
-5 (23.0)
WBT
-6 (21.2)