9

Maintenance

9.1. Washing
Remove heavy soiling after each use. Before washing, remove accumulator from glove and close the zipper of the
inner pocket. Wash the gloves in the protective textile bag that came with the gloves in the packaging. Place the back
of the left glove with the electronics in the palm of the right glove so that the IR sensor is protected by the palm of
the right glove (Fig. 5).
Fig. 5
Place the gloves arranged in this manner in the washing bag and close the bag. Wash the gloves at a temperature up
to 60 °C. Do not use bleach or detergent. After washing and prior to drying, insert your hand into the gloves to shape
them. Open the pocket for the accumulator box and move the end of the connector out of the pocket.
9.2. Drying
When drying, do not place gloves directly on the heat source. Dry slowly. Do not dry in a dryer or microwave oven.
Under ideal conditions, we recommend the use of a circulating air dryer with air temperature of 45 °C to 50 °C – with
air circulating into the gloves and the surrounding area.
After drying, once again insert your hand into the gloves to shape them. Make sure the connector is dry. After
each washing and drying, check the functionality of the electronics; make sure the IR sensor and laser pointer are
unobstructed and that the head of the temperature sensor is clean and has direct contact with the air. The SensPro
application is ideal for checking glove functionality.
9.3. Regular control and maintenance
After each use, conduct a visual inspection of the gloves, especially the accumulator, all parts of the electronics and
the sensors. Keep the cover of the temperature sensor on the ring finger clean, and make sure that the IR sensor and
the laser pointer remain clean and unobstructed. Clean the area around the sensors gently. Should you discover any
damage or change in the volume of the parts, do not use the gloves. At the same time, check the seams and look for
any tears in the material. If you determine that the gloves are damaged to an extent that prevents proper protection
of the hands, do not use the gloves. These inspections are made by the user. No gloves can provide 100% protection.
Perform all work with caution!