Reading Temperatures And Light Signals - Holik SensPro Instruction For Operation And Maintenance

Protective gloves for firefighters
Table of Contents

Advertisement

5

Reading temperatures and light signals

5.1. Display of measured values
Visual display gives a possibility to divide the temperature range into 6 levels. Besides the first range, in which
only one green LED shines, two LEDs always shine at the same time. Five limit values can be set separately for the
temperature sensor and the IR sensor. Table 3 shows the factory settings for limit values.
BAR GRAPH
green
green
orange
orange
red
red LEDs blink
Tab. 2: Factory settings for limit values
The customer can change these values based on their specific needs. To do so, it is necessary to download the
SensPro
application, which is available for Android and Apple systems. Uncontrolled and frequently reset limit
®
values present a safety risk for professional fire brigades. For this reason, a password (provided with the gloves) is
required to make changes. The customer must set their own internal rules as to who is authorised to change values.
More information is available in the instructions for the SensPro
5.2. Measuring
When the glove is switched on, both the temperature sensor (1) and the IR sensor are immediately functional, and
temperatures are measured while the glove remains switched on. Switching between mode 1 (measuring with the
temperature sensor) and mode 2 (measuring with the IR sensor) only impacts the display of measured temperatures
on the bar graph. In mode 1, the bar graph displays the temperatures measured with the temperature sensor; in
mode 2, the bar graph displays temperatures measured with the IR sensor.
5.3. Measuring with the temperature sensor
The range of measuring with the temperature sensor is from -50 °C to +500 °C. The temperature sensor (1) is
located in the ring finger and is protected by a cover. The head of the temperature sensor is in direct contact with the
surrounding air at the edge of the cover. To prevent distorted readings, it is necessary to keep this area clean and
free from dust and dirt.
Holík International
Holík International
www.senspro.cz
Temperature sensor
orange
from 100 °C to 125 °C
orange
from 125 °C to 150 °C
red
from 150 °C to 175 °C
red
from 175 °C to 200 °C
Temperature range
<100 °C
>200 °C
®
application.
DE
EN
PL
FR
RU
ES
IR sensor
<100 °C
from 100 °C to 150 °C
from 150 °C to 200 °C
from 200 °C to 250 °C
from 250 °C to 300 °C
>300 °C
9