Operating Instructions Interlocking/Locking Modules
MGB2-I..-MLI-... / MGB2-L..-MLI-... (Modular)
Function
Module connector M12, 5-pin, male
Blanking cover
Set with sealing caps for unused connections
Module connector, 5-pin, female for the direct connec-
tion of a further module
Module connector M12, 5-pin, female for the connec-
tion of a further module via a connecting cable
Module connector for the connection of a Stacklight
Connecting cable M12, 5-pin
13.2.

Using submodules

Each interlocking/locking module can contain up to two submodules. For an exact description of the individual submodules
as well as information on compatibility, please refer to the data sheet for the related submodule. This is included with each
submodule.
Important!
Ì
In the modules described here it is only allowed to install submodules of connection types P, R and
N. For information on the related connection type of a submodule, please refer to the sticker on
the rear of the submodule or the data sheet for the related submodule. This is included with each
submodule.
Ì
Only one submodule with an emergency stop is allowed to be installed per module
Ì
On using a submodule with labeling fields, pay attention to the correct alignment of the modules in
relation to the labeling fields. Incorrect assignments can cause serious malfunctions in your instal-
lation.
Ì
Unused submodule slots must be fitted with a cover order number 126372.
Ì
Avoid touching the contacts on the underside of the submodule. Risk of ESD damage and contact
problems due to soiling.
30
Order no.
157024
156718
156739
157025
157028
157029
See catalog or www.euchner.com
(Translation of the original operating instructions) 2500234-01-08/18
Included?
1x
1x
Yes
No, must be ordered separately