Changing The Door Hinge Position; Changing The Interlocking/Locking Module To A Different Door Hinge Position; Changing Actuating Direction Of The Handle Module - EUCHNER MGB2-Ixx-MLI series Operating Instructions Manual

Interlocking / locking modules
Table of Contents

Advertisement

Operating Instructions Interlocking/Locking Modules
MGB2-I..-MLI-... / MGB2-L..-MLI-... (Modular)

10. Changing the door hinge position

10.1.

Changing the interlocking/locking module to a different door hinge position

To change the interlocking/locking module for doors with a different door hinge position, the module only needs to be
rotated by 180°. Submodules installed in the module can also be rotated by 180° (see section 9.1. Replacing modules on
page 23 ).
10.2.

Changing actuating direction of the handle module

(Here: from right to left)
Important!
It is possible to make this change only when the bolt tongue is not extended and an escape release
is not yet mounted.
As supplied, the handle module is set either for doors hinged on the right or for doors hinged on the left.
Based on the example of a handle module for doors hinged on the right this means:
Ì
The guard opens by pressing down the door handle.
Ì
The system is mounted the other way up for doors hinged on the left. In other words, the guard opens by pressing up
the door handle (see Figure 10). For this reason the actuating direction of the door handle must be changed (see Figure
10 to Figure 15).
(Similarly on handle modules for doors hinged on the left)
26
(Translation of the original operating instructions) 2500234-01-08/18