Preparing Escape Release - EUCHNER MGB2-Ixx-MLI series Operating Instructions Manual

Interlocking / locking modules
Table of Contents

Advertisement

8.3.1. Preparing escape release

Profile width
Length required for actuation
axis
Without
With mounting
mounting
plates
plates
(4 mm each)
D
D+9
30 mm
39 mm
40 mm
49 mm
45 mm
54 mm
50 mm
59 mm
Example without mounting plates:
Escape release
Handle module
3
1 Insert actuation axis. The snap ring A must be in contact with the escape release B.
2 Fit door handle.
3 Tighten fixing screw to 2 Nm and press in cap.
4 Fit protective sleeve.
Figure 7:
Preparing escape release
2500234-01-08/18 (Translation of the original operating instructions)
Which EUCHNER parts are required?
D+17
47 mm
Standard escape release
with 107 mm axis
(order no. 100465)
57 mm
Standard escape release
with 107 mm axis
(order no. 100465)
If necessary,
extended actuation axis (order no. 106761)
62 mm
Standard escape release
with 107 mm axis
(order no. 100465)
and
extended actuation axis (order no. 106761)
67 mm
Standard escape release
with 107 mm axis
(order no. 100465)
and
extended actuation axis (order no. 106761)
1
2
Operating Instructions Interlocking/Locking Modules
MGB2-I..-MLI-... / MGB2-L..-MLI-... (Modular)
Necessary work steps
Shorten to required length
Without mounting plates:
None
With mounting plates:
Use extended actuation axis and protective sleeve and
shorten to required length
Use extended actuation axis and protective sleeve and
shorten to required length
Use extended actuation axis and protective sleeve and
shorten to required length
Actuation axis
Protective sleeve
M4
A
4
B
21
EN