Setup ......................... 10 Operation ......................10 Status and fault displays ..................11 12.1. Smartcard status and fault displays....................11 12.2. EKS2 status and fault displays .......................12 12.3. Firmware status display .........................13 Technical data ....................14 13.1. Technical data for EKS2 ........................14 13.2.
Electronic-Key-System EKS2 1. About this document 1.1. Scope These operating instructions apply to all EKS2-C-USB-M-I1S1-B1-… from version V1.0.0. These operating instructions, the supplementary documents and any enclosed data sheet form the complete user information for your device. 1.2. Target group...
Ì EN ISO 13849-1 Ì EN 60204-1 The device may be operated only with suitable smartcards and the EUCHNER connection components. On the use of unsuit- able smartcards or other connection components, EUCHNER provides no warranty for safe function. Important! Ì The user is responsible for the proper integration of the device into a safe overall system. For this purpose, the overall system must be validated, e.g.
Operating Instructions Electronic-Key-System EKS2 3. Description of the safety function Devices from the series EKS2-… feature the following safety function: Safe switching and monitoring of the selected operating mode (subsystem of the safety function selection of operating mode according to EN ISO 13849-1) Ì...
Page 6
Operating Instructions Electronic-Key-System EKS2 The data structure of selection of operating mode is hierarchically structured for the individual authorization levels, and it changes values accordingly in the individual polling levels. MSO1 MSO2 MSO3 MSO4 MSO SE 0F0FH 0FF0H 3333H 33CCH...
1) Operating mode change: state duration from 2 to max. 60 ms; safe state: state duration longer than 60 ms. 2) The subsystem EKS2 is in the safe state. An error must be reported to the control system. The LED illumination of the card holder indicates the status and error messages (see chapter 12. Status and fault displays on page 11).
Operating Instructions Electronic-Key-System EKS2 7. Smartcards Various smartcards are available for the device. They differ regarding the type and scope of authorization for selection of operating mode MO. Order number Smartcard Selectable operating modes 3875478 Mode 1 (MO1) Automatic mode...
Operating Instructions Electronic-Key-System EKS2 9. Electrical connection 9.1. General notes WARNING Loss of the safety function due to incorrect electrical connection. Ì Ensure that at least four of the safety outputs FO1A to FO1F can be evaluated by a safe control system at all times.
Operating Instructions Electronic-Key-System EKS2 9.3. Terminal assignment Connection terminal FO1F FO1E MO Service FO1D FO1C FO1B FO1A Ground 0 V Operating voltage 24 V DC USB interface The device is connected to the touch panel using the permanently mounted USB cable.
Operating Instructions Electronic-Key-System EKS2 12. Status and fault displays The card holder’s LED illumination indicates the individual status and error messages. Detailed error messages can be output on the touch panel. LED not illuminated LED illuminated Key to symbols 5 Hz LED flashes at 5 Hz...
Operating Instructions Electronic-Key-System EKS2 12.2. EKS2 status and fault displays (translation of the original operating instructions) 2546099-01-10/21...
Operating Instructions Electronic-Key-System EKS2 12.3. Firmware status display LED indicator Meaning green Firmware update See “Normal operation” Firmware data are sent to the device during normal operation. 5 Hz The firmware update is activated via a separate command. The firmware update was successful. Acknowledge flashing code by restart or separate command.
Operating Instructions Electronic-Key-System EKS2 13. Technical data 13.1. Technical data for EKS2 Parameter Value Unit min. typ. max. General Material Polyamide PA66 Installation orientation On side Degree of protection in the installed state IP54 at front, IP20 in panel Safety class...
Operating Instructions Electronic-Key-System EKS2 13.2. Radio frequency approvals FCC ID: 2AJ58-14 22052-14 FCC/IC-Requirements This device complies with part 15 of the FCC Rules and with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation.
Operating Instructions Electronic-Key-System EKS2 13.3. Dimension drawing for EKS2… Socket strip Z 2 : 1 (translation of the original operating instructions) 2546099-01-10/21...
The year of manufacture can be seen in the lower right corner of the type label. The current version number in the format (V X.X.X) can also be found on the device. 15. Service If servicing is required, please contact: EUCHNER GmbH + Co. KG Kohlhammerstraße 16 70771 Leinfelden-Echterdingen Germany...