OPEN
CLOSED
1 Press door handle up.
Figure 10:
Changing actuating direction, step 1
4
4 Lift the locking pin on the door handle using a screwdriver and hold
it in this position.
5 Turn door handle to the right.
Figure 12:
Changing actuating direction, steps 4 and 5
9 Remove cap and undo screw.
AT Reposition the door handle by 90° in clockwise direction and fasten it
again.
A Tighten screw to 2 Nm and re-fit cap.
Figure 14:
Changing actuating direction, steps 9 and A
2500234-01-08/18 (Translation of the original operating instructions)
5
11
9
T10
10
Operating Instructions Interlocking/Locking Modules
MGB2-I..-MLI-... / MGB2-L..-MLI-... (Modular)
3
2
2 Unscrew locking screws.
3 Push cover aside.
Figure 11:
Changing actuating direction, steps 2 and 3
a
7
8
6 Only if using an escape release: Using the Torx 10, turn the joint
counterclockwise from position (a) to position (b).
7 Close cover.
8 Screw in locking screws and tighten to 0.8 Nm.
Figure 13:
Changing actuating direction, steps 6 to 8
CLOSED
OPEN
A State after repositioning.
Figure 15:
Changing actuating direction, final state
b
6