Connecting Load And Solar Module - EFOY ProCube 2060A User Manual

Table of Contents

Advertisement

Available languages

Available languages

3. Operation

3.7 Connecting Load and Solar Module

*Example illustration: Steca Solsum 10.10F
Depending on the version of the EFOY ProCube 2060A there will be a cable gland or a plug
as connection for the load (see document "specific product information")
*Example illustration
*Example illustration
INFO:
If the outer plugs are not in use the caps must be used to prevent
contamination of the plugs.
INFO:
Connect loads that must not be deactivated by the solar charge controller deep
discharge protection, e.g.: emergency lights / radio connection directly to the
battery.
Please read the user manual of the solar charge
controller carefully prior to installing and connecting
loads and solar module via the integrated solar charge
controller.
Loads with a higher current consumption than the
device output can be directly connected to the battery.
However, the solar charge controller deep discharge
protection will no longer intervene. Loads connected in
this manner must also be separately fused.
Cable gland: The cable glands are in the package of the
accessories. Please screw them on instead of the blind plugs. Feed
the load and solar module connection cable each through one of the
two cable glands on the EFOY ProCube. Connect the load and solar
module cables directly to the solar charge controller.
Plug: Please refer to the enclosed manual assembly and wiring
instruction for wiring operations.
16