3. Operation
3.5 Connecting the Fuel Cartridge
DANGER!
Use only intact original EFOY fuel cartridges!
INFO:
The EFOY fuel cartridge is tested for tightness using the wet-control paper.
1
2
3
Place the wet-control paper in the foreseen space of
the EFOY fuel cartridges.
Place a new sealed original-equipment EFOY fuel
cartridge in the foreseen space in the EFOY
ProCube. Make sure the EFOY fuel cartridge is not
wet. If necessary, wipe them dry.
After a minute, check the wet-control paper at the
bottom of the fuel cartridge area for wetness. If the
wet-control paper is wet, check your EFOY fuel
cartridge for damage and if necessary replace it
with another EFOY fuel cartridge.
Only remove the childproof cap when the new fuel
cartridge has been placed.
If a M5 or M10 fuel cartridge is used screw the EFOY
Pro fuel cartridge connector directly onto the fuel
cartridge.
The M28 adapter is required to connect the M28
cartridge to the EFOY Pro.
Connect the EFOY Pro fuel cartridge connector (1)
with the M28 adapter (2).
Screw the M28 adapter (2) onto the M28 fuel
cartridge (3).
14