3. Operation

3.1 Installation Space Requirements

DANGER!
The EFOY ProCube must not be used continuously in closed interior.
WARNING!
Installation and maintenance has to be done by authorized personnel only who
are familiar with all valid safety rules and guarantee the adherence of these
rules. During installation of additional equipment compliance with the EMC
directive (2014/30/EU) must be observed.
Do not operate unit if there is danger of explosion.
The EFOY ProCube and the EFOY Pro fuel cell are not watertight. Make sure
that no water can enter.
Avoid places of installation with direct solar radiation in warm surrounding
areas.
max +50 °C / +122 °F
min -20 °C / -4 °F
INFO:
The unit requires air from the outside and generates off-heat that needs to be
conducted to the outside. Please take this into account when considering
possible locations.
Front
inlet
3.
Operati on
Make sure when choosing an installation space of the
EFOY ProCube that the temperature ranges of the EFOY
Pro fuel cell and the EFOY fuel cartridges do comply.
The air openings must not be blocked.
Install the EFOY ProCube only in upright position.
The lid needs to be free so that it can be opened.
Make sure that the device does not exceed the maximum
inclination.
Inclination along the direct axis: 35 ° (temporary 45 °)
Inclination along the quadrature axis: max. 20 °
outlet
11