VITA FiringAssist i-Line Program for processing VITA V60 i-Line fi ring programs on the PC ® Operating manual VITA Farbkommunikation VITA Farbkommunikation VITA shade determination VITA shade communication VITA shade reproduction VITA shade control Issued 12.16 VITA shade, VITA made.
Transfering a new program list to the PC Exporting a program list from VITA FiringAssist i-Line to PC Importing a program list from PC to VITA FiringAssist i-Line Transfering a program from VITA Vacumat 6000 M / MP to VITA FiringAssist i-Line...
– Indicate the installation path during the installation (e.g., C:\Programme\v60tool). After the program is successfully installed, there will be a new menu item with the name VITA FiringAssist i-Line in the Start menu. In the VITA FiringAssist i-Line program, these instructions and an uninstallation routine can be called up there.
VITA FiringAssist i-Line – Operating manual 3 Functions of the VITA FiringAssist i-Line The VITA FiringAssist i-Line program window can be seen in Fig. 1. Fig. 1: VITA FiringAssist i-Line program window...
Save the program list found in the right-hand table Symbol (Delete) Delete a saved program list Symbol (Prepare) Prepare USB flash drive for accepting a program list from a VITA V60 i-Line Symbol (Import) Import program list from USB flash drive into VITA FiringAssist i-Line Symbol (Export)
VITA FiringAssist i-Line – Operating manual 3.2 Functions of the left-hand and right-hand tables Fig. 3: Left-hand and right-hand table In the lower area of the program window are two tables with different functions and possibilities for action: Table 1: Left-hand and right-hand table with function options...
Page 8
VITA FiringAssist i-Line – Operating manual Table 3: Right-hand table – Action possibilities Reaction Action Program is selected. Firing parameters of this program can be Single click on a program processed in the firing curve. See 3.3 "Processing program values"...
3.3 Processing of program values The upper area of the program window shows a firing curve image like the one present in the VITA V60 i-Line. Here, the firing program values of a program can be changed in the right-hand table.
VITA FiringAssist i-Line – Operating manual 3.4 Creating a new program The creation of a new firing program is possible in the right-hand table. – Mark the program in the right-hand table under which the new program is to be placed.
VITA FiringAssist i-Line – Operating manual 3.5 Save a program list The firing program list in the right-hand table can be saved. – Click on the symbol (Save). Alternatively, you can select Save under File Save. – Enter the new name of the program list in the name window and confirm.
When the program list overview is opened again using the symbols (Open) or (Delete), the deleted program list is no longer available. Program lists with a preceding underscore (VITA = long, other = short) are pre-installed in the factory. These cannot be deleted.
Alternatively, you can select Prepare under File Prepare V60. Tip: If you want to export the program list from a VITA V60 i-Line and do not have the VITA FiringAssist i-Line readily available, you can install an empty folder with the name "programs" on the USB flash drive. This corresponds to the preparation on the VITA FiringAssist i-Line.
Now the imported program list is displayed in the left-hand table of the program window (Fig. 11). Fig. 11: Imported program list in left-hand table Save a backup copy of the program list in the VITA FiringAssist i-Line. See 3.5 "Saving a program list."...
4.4 Preparing a USB flash drive for further use – To prevent any future unwanted overwrite of a program list in a VITA V60 i-Line, delete this program list from the USB flash drive after the successful transfer of the program list into the VITA FiringAssist i-Line.
– Turn the VITA V60 i-Line on at the main switch. After switching the VITA V60 i-Line on, the entire, new program list is imported from the USB flash drive to the VITA V60 i-Line. The program list pre-installed in the VITA V60 i-Line will be overwritten! –...
5.3 Preparing the USB flash drive for further use To prevent any future unwanted overwrite of a program list in a VITA V60 i-Line, delete this program list from the USB flash drive after the successful transfer of the new program list.
– Operating manual 6 Transfering a new program list to the PC The program lists contained in the VITA FiringAssist i-Line can be saved on the PC in order to be able to send them by email, for instance. 6.1 Exporting a program list from VITA FiringAssist i-Line to PC –...
– Click on the program file that appears The name of the program file appears in the "File name" input field. – Click on "Select file" below right. The program list is displayed in the left-hand table in the VITA FiringAssist i-Line.
The VITA FiringAssist i-Line offers the possibility of transferring VITA Vacumat 6000 M / MP programs from the VITA vPad to the VITA FiringAssist i-Line and converting them into VITA V60 i-Line programs. – Insert an empty USB flash drive into the VITA vPad and export the desired profile to an empty USB flash drive. See VITA vPad Operating Manual.
Page 21
VITA FiringAssist i-Line – Operating manual A list of all profiles that can be transferred to the VITA FiringAssist i-Line appears. Fig. 18: Select the profile from the VITA Vacumat 6000 M / MP. – In the new window, click ("Import Vacumat programs") on the desired profile and confirm (or double click on the program list).
Page 22
VITA FiringAssist i-Line – Operating manual...
Page 24
Claims for damages based on fault liability (fault in making the contract, breach of contract, unlawful acts, etc.) can only be made in the case of intent or gross negligence. The VITA Modulbox is not necessarily a component of the product.