Plan
We recommend you to do not use other applications while the computer transfers
dates to the plotter (while the progress bar is still active). Otherwise the computer may
loose dates or freeze the plotter.
-
The progress bar disappears after transfer datas ends, the button becomes
unactve and on it appears a new message: Disconnected plotter.
-
The plotter plots until the end of the file.
The speed of the transfer data is greater than the speed of the plotting. This is
why the plotter still plots after the progress bar disappears.
Chapter 8:

8.1 Lubricating

Clean and lubricate the contact surface between paper and plotter with a soft piece
of fabric oil softened. Do this on each 2 weeks or as many times as it is necessary.
Lubricate the bearings, the jacks feed paper reel spindle and jacks recovering
paper reel spindle using fine oils on each 2 weeks or as many times as it is necessary.

8.2 Cleaning

Clean with alcohol the pressure whiles because during the plotting process
impurities from refill and from paper are deposed on these elements. Do this on each
2 weeks or as many times as it is necessary.You must keep clean the plotter!

8.3 Recalibrate

The plotter must be calibrating once a month, or as many times as it is necessary
(when the plotted files dimensions are different from the project dimensions).

8.4 Check the plotting quality

Each plotted file must be checked (by measuring) before using it in production. If
the measured dimensions are the same with those from the project the marker can be
used in production.