wtw SensoLyt ORP 900-P Operating Manual

Ids orp electrode

Advertisement

Quick Links

OPERATING MANUAL
OPERATING MANUAL
ba75993e03 06/2017
®
SensoLyt
ORP 900-P
IDS ORP ELECTRODE

Advertisement

loading

Summary of Contents for wtw SensoLyt ORP 900-P

  • Page 1 OPERATING MANUAL OPERATING MANUAL ba75993e03 06/2017 ® SensoLyt ORP 900-P IDS ORP ELECTRODE...
  • Page 2 ® SensoLyt ORP 900-P Copyright © 2017, Xylem Analytics Germany GmbH Printed in Germany. ba75993e03 06/2017...
  • Page 3: General Information

    ® SensoLyt ORP 900-P General information General information Automatic sensor The sensor electronics with the stored sensor data are in the connecting recognition head of the electrode. The data include, among other things, the sensor type and series number. The data is recalled by the meter when the sensor is connected and is used for measurement and for measured value documen- tation.
  • Page 4 ® General information SensoLyt ORP 900-P Commissioning, measuring, calibration Opening and closing the IDS plug connection ® This section only applies to variants with IDS plug (SenTix ... -P). Plug connection closed and locked Guidance Groove Opening the plug  If necessary, clean the plug connection. connection ...
  • Page 5 ® SensoLyt ORP 900-P General information Commissioning ® Scope of delivery  ORP electrodeSensoLyt ORP 900-P  Operating manual Commissioning Prepare the electrode for measuring as follows:  Remove the watering cap from the electrode tip. Possible salt deposits in the area of the watering cap do not affect the measuring characteristics and can easily be removed with deionized water.
  • Page 6 ® Aging SensoLyt ORP 900-P T (°C) [mV] T (°C) [mV] ® ® SensoLyt ORP 900-P SensoLyt ORP 900-P +221 +187 +216 +181 +212 +176 +207 +171 +202 +165 +197 +160 +192 Aging ORP electrodes are consumables. Every ORP electrode undergoes a natural aging process.
  • Page 7: Technical Data

    ® SensoLyt ORP 900-P Cleaning Cleaning Cleaning Contamination Cleaning procedures Gross contamination on the junction Carefully brush off contamination under running water using a soft toothbrush Fats, oils, protein-containing sedi- Remove with household washing- ments and similar substances up liquid Technical data Shaft dimensions, Shaft length...
  • Page 8: Wear Parts And Accessories

    ® Wear parts and accessories SensoLyt ORP 900-P Accuracy of the Measured parameter Accuracy (± 1 digit) IDS measuring U [mV] ± 0.2 technique T [°C] ± 0.1 Temperatureallowed overpressure Pressure range at 0 °C (32 °F) 1000 kPa (10 bar) temperature 20 °C (68 °F) 1000 kPa (10 bar)
  • Page 9 ® SensoLyt ORP 900-P Disposal Radio connection Description Model Order no. ® SensoLyt WLM capable IDS meter see Internet 900-P - meter + radio module for IDS meter Radio module for plug head sensor IDS WLM-S 108 141 General purpose Description Model Order no.
  • Page 10 ® Disposal SensoLyt ORP 900-P ba75993d03 06/2017...
  • Page 12 For more information on how Xylem can help you, go to xyleminc.com. ® Service address: Xylem Analytics Germany Sales GmbH & Co. KG Dr.-Karl-Slevogt-Str. 1 82362 Weilheim Germany Tel.: +49 881 183-325 Fax: +49 881 183-414 E-Mail wtw.rma@xyleminc.com Internet: www.WTW.com Xylem Analytics Germany GmbH Dr.-Karl-Slevogt-Str. 1 82362 Weilheim Germany...