Technotherm VPS series Operating Instructions Manual page 10

Table of Contents

Advertisement

Installation and Operating Instructions
VPS devices
9. Installation of Electricity
The device was developed for an electrical voltage of 230 V(nominal) and an alternating current of (AC)
50 Hz. The electrical installation may only be performed according to the user manual and only by a
qualified Electrician. The device was designed to be used with termination and the connection cable
has to be plugged into an appropriate socket at all times. (Notice Permanent cables may not be used)
The distance between the receptacle and the device hast to be at least 10cm. The connection line may
not touch the device at any time.
10. Regulation
From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of the
GB
Ecodesign requirements 2015/1188.
The installation and commissioning of the devices is only permitted in conjunction with external room
temperature controllers that fulfill the following functions:
• electronic room temperature control
and has at least one of the following properties:
• room temperature control, with presence detection
• room temperature control, with open window detection
• with distance control option
• with adaptive start control
The following room temperature controller systems
• RF Receiver together with the TPF-Eco Thermostat (Art.Nr.: 750 000 641) and the Eco-Interface
(Art.Nr.750 000 640) or
• DSM-Thermostat with the DSM-Interface (Art.No.:911 950 101)
• TDI- Thermostat / plus-Thermostat
from Technotherm meet the following requirements and therefore the ErP Directive:
• electronic room temperature control plus week timer (RF/DSM/TDI)
• room temperature control, with open window detection (DSM/plus/TDI)
• with distance control option (DSM/RF)
• with adaptive start control (DSM/plus/TDI)
Use of the VPS / VP Standard range (without external/internal thermostat control) is only permit-
ted on feet.
Installation of the receiver and the interfaces see separate instructions. For customer service - see last
page.
Failure to comply with these requirements will result in the loss of the CE mark.