SECTION 5: INTERFACE SPECIFICATIONS

5.3 IEEE1284 PARALLEL INTERFACE

The parallel interface for this printer conforms to the IEEE1284 specification. It will
automatically detect the IEEE1284 signals and operate in the high speed mode. If it does
not detect the IEEE1284 signals, it will operate in the standard Centronics mode, which
is significantly slower. For this reason, an interface cable and host interface conforming
to the IEEE1284 specification must be present to fully utilize the speed capabilities. This
interface also operates bidirectionally and can report the status of the printer back to the
host.
Electrical Specifications
Printer Connector
Cable Connector
Cable Length
Signal Level
PIN
SIGNAL
1
STROBE
2
DATA 1
3
DATA 2
4
DATA 3
5
DATA 4
6
DATA 5
7
DATA 6
8
DATA 7
9
DATA 8
10
ACK
11
BUSY
12
PTR ERROR
13
SELECT
14
AUTOFD (1)
15
Not Used
16
Logic Gnd
17
FG
18
+5V(Z=24Kohm)
(1)
Signals required for IEEE1284 mode
Page 5-4
AMP 57-40360 (DDK) or equivalent
AMP 57-30360 (DDK) or equivalent
10 ft. (3 m) or less
High = +2.4V to +5.0V Low = 0V to -0.4V
DIRECTION
PIN
To Printer
19
To Printer
20
To Printer
21
To Printer
22
To Printer
23
To Printer
24
To Printer
25
To Printer
26
To Printer
27
To Host
28
To Host
29
To Host
30
To Host
31
To Host
32
33
34
Frame Ground
35
To Host
36
SIGNAL
DIRECTION
STROBE Return
Reference
DATA 1 Return
Reference
DATA 2 Return
Reference
DATA 3 Return
Reference
DATA 4 Return
Reference
DATA 5 Return
Reference
DATA 6 Return
Reference
DATA 7 Return
Reference
DATA 8 Return
Reference
ACK Return
Reference
BUSY Return
Reference
PE Return
Reference
INIT
From Host
FAULT
To Host
Not Used
Not Used
Not Used
From Host
(1)
SELECTIN
SATO D508/D512 Operator Manual