MAINTENANCE

DISCONNECT MACHINE FROM POWER SOURCE
BEFORE PERFORMING MAINTENANCE ON MACHINE!
CAMERA CLEANING
After every use, the camera should be cleaned and checked for possi-
ble damage that may have occurred during the inspection. External
scuffing of the camera housing is normal and should be of no con-
cern; however, use the trap skid to protect the camera and help it
slide around elbows more easily.
The camera lens is made of sapphire and should be cleaned with a
soft, damp cloth. Grease, dirt, or scratches will affect the quality of the
video picture.
CABLE AND REEL ASSEMBLY CLEANING
WHEN CLEANING THE REEL ASSEMBLY DO NOT USE A
POWER WASHER. WATER MAY GET INTO UNSEALED AREAS
SUCH AS THE REEL HUB ASSEMBLY AND SLIP RING HOUSING
CAUSING DAMAGE AND VOIDING THE WARRANTY.
The cable and reel assembly should be kept clean from dirt. When
rewinding the cable back onto the reel after an inspection, it is good
practice to use a clean rag to wipe off any debris the cable may have.

TROUBLESHOOTING

COMMAND MODULE
No Picture AND No Lights:
Check to see if the Main Power switch is ON. Check to make
sure the power source is "live" (for 120 volt AC) or check to see if
the light is lit on the cigarette lighter plug (for 12 volt DC).
Check to make sure that the camera lens is not covered or look-
ing at a surface that provides no detail, therefore any image de-
tail.
Check all connections and connectors from the camera back to
the Command Module, including the cable reel.
Disconnect main power and contact the factory service depart-
ment.
Picture BUT No Lights:
Check if Power switch is ON.
Check to see if LED Dimmer control (located on the panel of the
Command Module) is turned up.
Check cable for possible breaks or intermittent open circuits by
flexing the cable.
Disconnect main power and contact the factory service depart-
ment.
®
Gen-Eye Micro-Scope2
No Picture, Lights OK
Check Monitor power switch is ON. Check to make sure the
power source is "live" (for 120 volt AC) or that the battery is
charged.
Check the interface cord for possible damage or intermittent
problem by flexing the cable.
Check the Push-Rod for possible breaks or intermittent open
circuits by flexing the cable.
Disconnect the main power source and contact the factory ser-
vice department.
Dark Picture
Check the lights on the camera to see if it is not supplying suffi-
cient light due to weak, dirty, or burned out bulbs.
Check to see if the Light LED Dimmer control on the face of the
command module is turned up.
Disconnect the main power source and contact the factory ser-
vice department.
Bad or Grainy Picture
Check the camera lens for dirt, grime, scratches or other foreign
matter.
Check the lights in the camera head to see if they are not supply-
ing sufficient light due to weak, dirty, or burned out bulbs.
Check for external electrical noise being radiated by outside
sources, such as a power station, etc.
Check the Push-Rod for possible breaks or intermittent open
circuits by flexing the cable.
Disconnect the main power source and contact the factory ser-
vice department.
No Picture, only words on display after turning the
power on:
Check that the Probe Rod or push rod is correctly connected to
the display unit.
Unable to record still photos or video:
Flash drive not present, incorrectly inserted, full or faulty.
Check that a flash drive is present and correctly inserted
into display unit.
Check flash drive capacity.
Check if flash drive will work in other devices.
All Display unit functions frozen/failed:
Reboot system
Insert a pin into the hole located on the side of the dis-
play unit. The system will restart automatically.